For EPA LT2 – Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA December 2005

PDF Copy is here.

US EPA Logo

Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA

December 2005

EPA Method 1623 LT2 Cryptospoiridium


Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA December 2005

Office of Water (4607)

EPA 815-R-05-002

http://www.epa.gov/microbes/ December 2005

 


 

Acknowledgments

 

This method was prepared under the direction of William A. Telliard of the Engineering and Analysis Division within the U.S. Environmental Protection Agency (U.S. EPA) Office of Water. This document was prepared by CSC under a U.S. EPA contract, with assistance from its subcontractor, Interface, Inc.

The U.S. EPA Office of Water gratefully acknowledges the contributions of the following persons and organizations to the development of this method:

Mike Arrowood, Centers for Disease Control and Prevention, Division of Parasitic Diseases (MS-F13), 4770 Buford Highway, N.E., Atlanta, GA 30341-3724, USA

Phil Berger, Office of Groundwater and Drinking Water, U.S. Environmental Protection Agency, 401 M Street, S.W., Washington, DC 20460, USA

Jennifer Clancy, Clancy Environmental Consultants, Inc., P.O. Box 314, St. Albans, VT 05478, USA Kevin Connell, CSC, 6101 Stevenson Avenue, Alexandria, VA 22314, USA

Ricardo DeLeon, Metropolitan Water District of Southern California, 700 Moreno Avenue, LaVerne, CA 91760, USA

Shirley Dzogan, EnviroTest Laboratories, 745 Logan Avenue, Winnipeg, Manitoba R3E 3L5, Canada Mary Ann Feige (retired), Technical Support Center, Office of Ground Water and Drinking Water, U.S.

Environmental Protection Agency, 26 W. Martin Luther King Drive, Cincinnati, OH 45268-1320,

USA

Colin Fricker, Thames Water Utilities, Manor Farm Road, Reading, Berkshire, RG2 0JN, England   Carrie Moulton (Hancock), Technical Support Center, Office of Ground Water and Drinking Water, U.S.

Environmental Protection Agency, 26 W. Martin Luther King Drive, Cincinnati, OH 45268-1320,

USA

Stephanie Harris,Manchester Laboratory, U.S. Environmental Protection Agency, Region 10, 7411 Beach Drive East, Port Orchard, WA 98366, USA

Dale Rushneck, Interface, Inc., 3194 Worthington Avenue, Fort Collins, CO 80526, USA

Frank Schaefer III, National Exposure Research Laboratory, U.S. Environmental Protection Agency, 26

  1. Martin Luther King Drive, Cincinnati, OH 45268-1320, USA

Steve Schaub, Health and Ecological Criteria Division (4304), Office of Science and Technology, U.S. Environmental Protection Agency, 401 M Street, S.W., Washington, DC 20460, USA

Ajaib Singh, City of Milwaukee Health Department, 841 North Broadway, Milwaukee, WI 53202, USA Huw Smith, Department of Bacteriology, Scottish Parasite Diagnostic Laboratory, Stobhill NHS Trust,

Springburn, Glasgow, G21 3UW, Scotland

Timothy Straub, Lockheed Martin, 7411 Beach Drive East, Port Orchard, WA 98366, USA

William A. Telliard, Office of Science and Technology, U.S. Environmental Protection Agency, 401 M Street, S.W., Washington, DC 20460, USA

Cryptosporidium cover photo courtesy of the U.S. Centers for Disease Control

Giardia cover photo courtesy of CH Diagnostic & Consulting Service, Inc.

i

 

Disclaimer

 

This method has been reviewed by the U.S. EPA Office of Water and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use.

Questions regarding this method or its application should be addressed to: Carrie Moulton

Coordinator, Laboratory Quality Assurance Program for the Analysis of Cryptosporidium

U.S. Environmental Protection Agency Office of Ground Water and Drinking Water Technical Support Center, MC140

26 West Martin Luther King Drive Cincinnati, OH 45268-1320

(513) 569-7919

(513) 569-7191 (fax)

moulton.carrie@epa.gov

ii

 


 

Introduction

 

To support future regulation of protozoa in drinking water, the Safe Drinking Water Act Amendments of 1996 require the U.S. Environmental Protection Agency (EPA) to evaluate the risk to public health posed by drinking water contaminants, including waterborne parasites, such as Cryptosporidium and Giardia. To implement these requirements, EPA must assess Cryptosporidium and Giardia occurrence in raw surface waters used as source waters for drinking water treatment plants. EPA Method 1623 was developed to support this assessment.

Method Development and Validation

EPA initiated an effort in 1996 to identify new and innovative technologies for protozoan monitoring and analysis. After evaluating potential alternatives to the then-current method through literature searches, discussions with research and commercial laboratories, and meetings with experts in the field, the Engineering and Analysis Division within the Office of Science and Technology within EPA’s Office of Water developed draft Method 1622 for Cryptosporidium detection in December 1996. This Cryptosporidium-only method was validated through an interlaboratory study in August 1998, and was revised as a final, valid method for detecting Cryptosporidium in water in January 1999.

Although development of an acceptable immunomagnetic separation system for Giardia lagged behind development of an acceptable system for Cryptosporidium, an acceptable system was identified in  October 1998, and EPA validated a method for simultaneous detection of Cryptosporidium and Giardia in February 1999 and developed quality control (QC) acceptance criteria for the method based on this validation study. To avoid confusion with Method 1622, which already had been validated and was in use both domestically and internationally as a stand-alone Cryptosporidium-only detection method, EPA designated the new combined procedure EPA Method 1623.

The interlaboratory validated versions of Method 1622 (January 1999; EPA-821-R-99-001) and Method 1623 (April 1999; EPA-821-R-99-006) were used to analyze approximately 3,000 field and QC samples during the Information Collection Rule Supplemental Surveys (ICRSS) between March 1999 and February 2000. Method 1622 was used to analyze samples from March 1999 to mid-July 1999; Method 1623 was used from mid-July 1999 to February 2000.

Changes in the April 2001 Versions of the Methods

Both methods were revised in April 2001, after completion of the ICRSS and multiple meetings with researchers and experienced laboratory staff to discuss potential method updates. Changes incorporated in the April 2001 revisions of the methods (EPA-821-R-01-025 and EPA-821-R-01-026) included the following:

  •  Nationwide approval of modified versions of the methods using the following components:
    • (a) Whatman Nuclepore CrypTest™ filter
    • (b) IDEXX Filta-Max® filter
    • (c) Waterborne Aqua-Glo™ G/C Direct FL antibody stain
    • (d) Waterborne Crypt-a-Glo™ and Giardi-a-Glo™ antibody stains
  • Clarified sample acceptance criteria
  • Modified capsule filter elution procedure
  • Modified concentrate aspiration procedure
  • Modified IMS acid dissociation procedure
  • Updated QC acceptance criteria for IPR and OPR tests
  • Addition of a troubleshooting section for QC failures
  • Modified holding times
  • Inclusion of flow cytometry–sorted spiking suspensions

Changes in the June 2003 Versions of the Methods

Both methods were revised again in June 2003 to support proposal of EPA’s Long Term 2 Enhanced Surface Water Treatment Rule. Changes incorporated into the December 2002 versions include:

  • Nationwide approval of a modified version of the methods using the Pall Gelman Envirochek™ HV filter
  • Removal of Whatman Nuclepore CrypTest™ filter from the methods as a result of discontinuation of the product by the manufacturer
  • Nationwide approval of the use of BTF EasySeed™ irradiated oocysts and cysts for use in routine quality control (QC) samples
  • Minor clarifications and corrections
  • Rejection criteria for sample condition upon receipt
  • Guidance on measuring sample temperatures
  • Clarification of QC sample requirements and use of QC sample results
  • Guidance on minimizing carry-over debris onto microscope slides after IMS

Changes in the December 2005 Versions of the Methods

Both methods were revised again in 2005 to support promulgation of EPA’s Long Term 2 Enhanced Surface Water Treatment Rule. Changes incorporated into the June 2003 versions include:

  • Nationwide approval of the use of portable continuous-flow centrifugation as a modified version of the method. The product met all method acceptance criteria for Cryptosporidium using 50-L source water samples (but not Giardia, however, individual laboratories are permitted to demonstrate acceptable performance for Giardia in their laboratory).
  • Addition of BTF EasyStain™ monoclonal antibody stain as an acceptable reagent for staining in Methods 1622/1623. The product was validated through an interlaboratory validation study using the Pall Envirochek™ HV
  • Clarification of the analyst verification procedure
  • Clarification of sample condition criteria upon receipt

Performance-Based Method Concept and Modifications Approved for Nationwide Use

EPA Method 1623 is a performance-based method applicable to the determination of Cryptosporidium  and Giardia in aqueous matrices. EPA Method 1623 requires filtration, immunomagnetic separation of the oocysts and cysts from the material captured, and enumeration of the target organisms based on the results of immunofluorescence assay, 4′,6-diamidino-2-phenylindole (DAPI) staining results, and differential interference contrast microscopy.

iv

The interlaboratory validation of EPA Method 1623 conducted by EPA used the Pall Gelman capsule

filtration procedure, Dynal immunomagnetic separation (IMS) procedure, and Meridian sample staining procedure described in this document. Alternate procedures are allowed, provided that required quality control tests are performed and all quality control acceptance criteria in this method are  met.

Since the interlaboratory validation of EPA Method 1623, interlaboratory validation studies have been performed to demonstrate the equivalency of modified versions of the method using the following components:

  • Whatman Nuclepore CryptTest™ filter (no longer available)
  • IDEXX Filta-Max® filter
  • Pall Gelman Envirochek™ HV filter
  • Portable Continuous-Flow Centrifugation (PCFC)
  • Waterborne Aqua-Glo™ G/C Direct FL antibody stain
  • Waterborne Crypt-a-Glo™ and Giardi-a-Glo™ antibody stains
  • BTF EasyStain™ antibody stain
  • BTF EasySeed™ irradiated oocysts and cysts for use in routine QC samples

The validation studies for these modified versions of the method met EPA’s performance-based measurement system Tier 2 validation for nationwide use (see Section 9.1.2 for details), and have been accepted by EPA as equivalent in performance to the original version of the method validated by EPA. The equipment and reagents used in these modified versions of the method are noted in Sections 6 and 7 of the method.

Because this is a performance-based method, other alternative components not listed in the method may be available for evaluation and use by the laboratory. Confirming the acceptable performance of a modified version of the method using alternate components in a single laboratory does not require that an interlaboratory validation study be conducted. However, method modifications validated only in a single laboratory have not undergone sufficient testing to merit inclusion in the method. Only those modified versions of the method that have been demonstrated as equivalent at multiple laboratories on multiple water sources through a Tier 2 interlaboratory study will be cited in the method.

v

Table of Contents

1.0       Scope and Application……………………………………………………………………………………………… 1

2.0       Summary of Method………………………………………………………………………………………………… 1

3.0       Definitions……………………………………………………………………………………………………………… 2

4.0       Contamination, Interferences, and Organism Degradation…………………………………………. 2

5.0       Safety……………………………………………………………………………………………………………………. 3

6.0       Equipment and Supplies………………………………………………………………………………………….. 4

7.0       Reagents and Standards………………………………………………………………………………………….. 8

8.0       Sample Collection and Storage………………………………………………………………………………… 11

9.0       Quality Control……………………………………………………………………………………………………… 13

10.0     Microscope Calibration and Analyst Verification………………………………………………………. 21

11.0     Oocyst and Cyst Suspension Enumeration and Sample Spiking…………………………………… 28

12.0     Sample Filtration and Elution………………………………………………………………………………….. 36

13.0     Sample Concentration and Separation (Purification)………………………………………………… 46

14.0     Sample Staining…………………………………………………………………………………………………….. 51

15.0     Examination…………………………………………………………………………………………………………. 52

16.0     Analysis of Complex Samples………………………………………………………………………………….. 54

17.0     Method Performance……………………………………………………………………………………………… 55

18.0     Pollution Prevention………………………………………………………………………………………………. 55

19.0     Waste Management………………………………………………………………………………………………… 55

20.0     References……………………………………………………………………………………………………………. 55

21.0     Tables and Figures…………………………………………………………………………………………………. 57

22.0     Glossary of Definitions and Purposes………………………………………………………………………. 66

vi

Method 1623: Cryptosporidium and Giardia in Water

by Filtration/IMS/FA

 

1.0                   Scope and Application

  • This method is for the detection of Cryptosporidium (CAS Registry number 137259-50-8) and Giardia (CAS Registry number 137259-49-5) in water by concentration, immunomagnetic separation (IMS), and immunofluorescence assay (FA) microscopy. Cryptosporidium and Giardia may be verified using 4′,6-diamidino-2-phenylindole (DAPI) staining and differential interference contrast (DIC) microscopy. The method has been validated in surface water, but may be used in other waters, provided the laboratory demonstrates that the method’s performance acceptance criteria are
  • This method is designed to meet the survey and monitoring requirements of the U.S. Environmental Protection Agency (EPA). It is based on laboratory testing of recommendations by a panel of experts convened by EPA. The panel was charged with recommending an improved protocol for recovery and detection of protozoa that could be tested and implemented with minimal additional
  • This method identifies the genera, Cryptosporidium or Giardia, but not the species. The method cannot determine the host species of origin, nor can it determine the viability or infectivity of detected oocysts and
  • This method is for use only by persons experienced in the determination of Cryptosporidium and Giardia by filtration, IMS, and FA. Experienced persons are defined in Section 22.2 as analysts or principal analysts. Laboratories unfamiliar with analyses of environmental samples by the techniques in this method should gain experience using water filtration techniques, IMS, fluorescent antibody staining with monoclonal antibodies, and microscopic examination of biological particulates using bright-field and DIC
  • Any modification of the method beyond those expressly permitted is subject to the application and approval of alternative test procedures under 40 CFR Part 27.

2.0                   Summary of Method

  • A water sample is filtered and the oocysts, cysts, and extraneous materials are retained on the filter. Although EPA has only validated the method using laboratory filtration of bulk water samples shipped from the field, field-filtration also may be
  • Elution and separation
    • Materials on the filter are eluted and the eluate is centrifuged to pellet the oocysts and cysts, and the supernatant fluid is
    • The oocysts and cysts are magnetized by attachment of magnetic beads conjugated to

anti-Cryptosporidium and anti-Giardia antibodies. The magnetized oocysts and cysts are separated from the extraneous materials using a magnet, and the extraneous materials are discarded. The magnetic bead complex is then detached from the oocysts and cysts.

  • Enumeration
    • The oocysts and cysts are stained on well slides with fluorescently labeled monoclonal

antibodies and 4′,6-diamidino-2-phenylindole (DAPI). The stained sample is examined using fluorescence and differential interference contrast (DIC) microscopy.

1                                                      December 2005

 

  • Qualitative analysis is performed by scanning each slide well for objects that meet the size, shape, and fluorescence characteristics of Cryptosporidium oocysts or Giardia

cysts.

  • Quantitative analysis is performed by counting the total number of objects on the slide confirmed as oocysts or
  • Quality is assured through reproducible calibration and testing of the filtration, immunomagnetic

separation (IMS), staining, and microscopy systems. Detailed information on these tests is provided in Section 9.0.

3.0                   Definitions

  • Cryptosporidium is a genus of protozoan parasites potentially found in water and other media. The recent taxonomy of the genus Cryptosporidium includes the following species and their potential hosts: hominis (humans; formerly C. parvum genotype I; Reference 20.1); C. parvum (bovine and other mammals including humans; formerly genotype II;); C. baileyi and C. meleagridis (birds); C. muris (rodents); C. canis (dogs); C. felis (cats); C. serpentis (reptiles); and
  1. nasorum (fish). Cryptosporidium oocysts are defined in this method as objects exhibiting brilliant apple green fluorescence under UV light (FA-positive), typical size (4 to 6 µm) and shape (round to oval), and no atypical characteristics by FA, DAPI fluorescence, or DIC microscopy. Examination and characterization using fluorescence (FITC and DAPI stain) and DIC microscopy are required for exclusion of atypical organisms (e.g., those possessing spikes, stalks, appendages, pores, one or two large nuclei filling the cell, red fluorescing chloroplasts, crystals, spores, etc.).
  • Giardia is a genus of protozoan parasites potentially found in water and other media. The recent taxonomy of the genus Giardia includes the following species and their potential hosts: lamblia (also called G. intestinalis or G. duodenalis; humans and other mammals); G. muris (rodents); G. agilis (amphibians); G. psittaci and G. ardeae (birds). Recent molecular studies suggest the division of G. lamblia into multiple genotypes (Reference 20.2). Giardia cysts are defined in this method as objects exhibiting brilliant apple green fluorescence under UV light

(FA-positive), typical size (8 to 18 µm long by 5 to 15 µm wide) and shape (oval to round), and no atypical characteristics by FA, DAPI fluorescence, or DIC microscopy. Examination and characterization by fluorescence (FITC and DAPI stain) and DIC microscopy are required for exclusion of atypical organisms (e.g., those possessing spikes, stalks, appendages, pores, one or two large nuclei filling the cell, red fluorescing chloroplasts, crystals, spores, etc.).

  • Definitions for other terms used in this method are given in the glossary (Section 0).

4.0                   Contamination, Interferences, and Organism Degradation

  • Turbidity caused by inorganic and organic debris can interfere with the concentration, separation, and examination of the sample for Cryptosporidium oocysts and Giardia In addition to naturally-occurring debris, e.g. clays and algae, chemicals, e.g. iron, alum coagulants and polymers added to source waters during the treatment process may result in additional interference.
  • Organisms and debris that autofluoresce or demonstrate non-specific immunofluorescence, such as algal and yeast cells, when examined by epifluorescent microscopy, may interfere with the detection of oocysts and cysts and contribute to false positives by immunofluorescence assay (FA) (Reference 3).

December 2005                                         2

 

  • Solvents, reagents, labware, and other sample-processing hardware may yield artifacts that may cause misinterpretation of microscopic examinations for oocysts and cysts. All materials used must be demonstrated to be free from interferences under the conditions of analysis by running a method blank (negative control sample) initially and a minimum of every week or after changes in source of reagent water. Specific selection of reagents and purification of solvents and other materials may be
  • Freezing samples, filters, eluates, concentrates, or slides may interfere with the detection and/or identification of oocysts and
  • All equipment should be cleaned according to manufacturers’ instructions. Disposable supplies should be used wherever

5.0                   Safety

  • The biohazard associated with, and the risk of infection from, oocysts and cysts is high in this method because live organisms are handled. This method does not purport to address all of the safety problems associated with its use. It is the responsibility of the laboratory to establish appropriate safety and health practices prior to use of this method. In particular, laboratory staff must know and observe the safety procedures required in a microbiology laboratory that handles pathogenic organisms while preparing, using, and disposing of sample concentrates, reagents and materials, and while operating sterilization
  • The toxicity or carcinogenicity of each compound or reagent used in this method has not been precisely determined; however, each chemical compound should be treated as a potential health hazard. Exposure to these compounds should be reduced to the lowest possible level. The laboratory is responsible for maintaining current knowledge of Occupational Safety and Health Administration regulations regarding the safe handling of the chemicals specified in this method. A reference file of material safety data sheets should be made available to all personnel involved in these analyses. Additional information on laboratory safety can be found in References 20.4 through 7.
  • Samples may contain high concentrations of biohazards and toxic compounds, and must be handled with gloves. Reference materials and standards containing oocysts and cysts must also be handled with gloves and laboratory staff must never place gloves in or near the face after exposure to solutions known or suspected to contain oocysts and cysts. Do not mouth-pipette.
  • Laboratory personnel must change gloves after handling filters and other contaminant-prone equipment and reagents. Gloves must be removed or changed before touching any other laboratory surfaces or
  • Centers for Disease Control (CDC) regulations (42 CFR 72) prohibit interstate shipment of more than 4 L of solution known to contain infectious materials (see http://www.cdc.gov/od/ohs/biosfty/shipregs.htm for details). State regulations may contain similar regulations for intrastate commerce. Unless the sample is known or suspected to contain CryptosporidiumGiardia, or other infectious agents (e.g., during an outbreak), samples should be shipped as noninfectious and should not be marked as infectious. If a sample is known or suspected to be infectious, and the sample must be shipped to a laboratory by a transportation means affected by CDC or state regulations, the sample should be shipped in accordance with these

3                                                      December 2005

 

6.0                   Equipment and Supplies                                                                   

NOTE:   Brand names, suppliers, and part numbers are for illustrative purposes only. No

endorsement is implied. Equivalent performance may be achieved using apparatus and materials other than those specified here, but demonstration of equivalent performance that meets the requirements of this method is the responsibility of the laboratory.

  • Sample collection equipment for shipment of bulk water samples for laboratory filtration. Collapsible LDPE cubitainer for collection of 10-L bulk sample(s)—Cole Parmer cat. no. U- 06100-30 or Fill completely to ensure collection of a full 10-L sample. Discard after one use.
  • Equipment for sample filtration. Four options have been demonstrated to be acceptable for use with Method 1623. Other options may be used if their acceptability is demonstrated according to the procedures outlined in Section 1.2.
    • Cubitainer spigot to facilitate laboratory filtration of sample (for use with any filtration option)—Cole Parmer cat. no. U-06061-01, or
    • Original Envirochek™ sampling capsule or Envirochek™ HV sampling capsule

equipment requirements (for use with the procedure described in Section 12.2). The versions of the method using these filters were validated using 10-L and 50-L sample volumes, respectively. Alternate sample volumes may be used, provided the laboratory demonstrates acceptable performance on initial and ongoing spiked reagent water and source water samples (Section 9.1.2).

  • Sampling capsule
    • Envirochek™, Pall Corporation, Ann Arbor, MI, part

12110 (individual filter) and or part no.12107 (box of 25 filters) (www.pall.com or (800) 521-1520 ext. 2)

  • Envirochek™ HV, Pall Corporation, Ann Arbor, MI, part
  1. 12099 (individual filter) or part no.12098 (box of 25 filters) (www.pall.com or (800) 521-1520 ext. 2)
  • Laboratory shaker with arms for agitation of sampling capsules
    • Laboratory shaker—Lab-Line model 3589 (available

through VWR Scientific cat. no. 57039-055), Pall Corporation part no. 4821, Fisher cat. no. 14260-11, or equivalent

  • Side arms for laboratory shaker—Lab-Line Model 3587-

4 (available through VWR Scientific cat. no. 57039-045), Fisher cat. no. 14260-13, or equivalent

  • Filta-Max® foam filter equipment requirements (for use with the procedure described in

Section 12.3). The version of the method using this filter was validated using 50-L sample volumes; alternate sample volumes may be used, provided the laboratory demonstrates acceptable performance on initial and ongoing spiked reagent water and matrix samples (Section 9.1.2).

December 2005                                         4

 

  • Foam filter—Filta-Max®, IDEXX, Westbrook, ME. Filter module cat. no. FMC 10603

NOTE:  Check at least one filter per batch to ensure that the filters have not  been

affected by improper storage or other factors that could result in brittleness or other problems. At a minimum confirm that the test filter expands properly in water before using the batch or shipping filters to the field.

  • Filter processing equipment—Filta-Max® starter kit, IDEXX,

Westbrook, ME, cat. no. FMC 11002. Starter kit includes manual wash station with clamp set (FMC 10101 or 10106) including plunger head (FMC 12001), tubing set (FMC 10307), vacuum set (FMC 10401), MKII filter housing with hose-tail fittings (FMC 10504) and green housing tools (FMC 10506). In addition, processing requires magnetic stirrer (FMC 10901) and filter membranes, 100 pk, (FMC 10800).

  • Portable Continuous-Flow Centrifuge (PCFC) requirements (for use with procedures

described in Section 12.4). The version of the method using this technique was validated for Cryptosporidium in 50-L sample volumes; alternate sample volumes may be used, provided the laboratory demonstrates acceptable performance on initial and ongoing spiked reagent water and matrix samples (Section 9.1.2). Individual laboratories are also permitted to demonstrate acceptable performance for Giardia in their laboratory. The technique is based on technology from Haemonetics Corporation, Braintree, MA.

  • Ancillary sampling equipment
    • Tubing—Glass, polytetrafluoroethylene (PTFE), high-density polyethylene (HDPE), or

other tubing to which oocysts and cysts will not easily adhere, Tygon formula R-3603, or equivalent. If rigid tubing (glass, PTFE, HDPE) is used and the sampling system uses a peristaltic pump, a minimum length of compressible tubing may be used in the pump.

Before use, the tubing must be autoclaved, thoroughly rinsed with detergent solution, followed by repeated rinsing with reagent water to minimize sample contamination. Alternately, decontaminate using hypochlorite solution, sodium thiosulfate, and multiple reagent water rinses. Dispose of tubing after one use whenever possible or when wear is evident.

  • Flow control valve—0.5 gpm (0.03 L/s), Bertram Controls, Plast-O-Matic cat.

FC050BΩ-PV, or equivalent; or 0.4- to 4-Lpm flow meter with valve, Alamo Water Treatment, San Antonio, TX, cat. no. R5310, or equivalent

  • Pump— peristaltic, centrifugal, impeller, or diaphragm pump; MasterFlex I/P®

EasyLoad® peristaltic pump (Cole-Parmer cat. No. EW-77963-10) with 77601-10 pumphead, 77410-00 drive unit, and 06429-73 Tygon LFL tubing; Dayton, model number 3YU61 (available through Grainger), Jabsco Flexible Impeller Pump (Cole- Parmer cat. No. EW-75202-00); Simer, model number M40; or equivalent. It is recommended that the pump be placed on the effluent side of the filter, when possible, to reduce the risk of contamination and the amount of tubing replaced or cleaned.

  • Flow meter—SaMeCo cold water totalizer, E. Clark and Associates, Northboro, MA,

product no. WFU 10.110; Omega flow meter, Stamford, CT, model FTB4105; or equivalent. Alternatively, use a graduated carboy(s) (See Section 6.18)

  • Equipment for spiking samples in the laboratory
    • Collapsible 10-L LDPE cubitainer with cubitainer spigot—Cole Parmer cat. no. U-

06100-30 or equivalent and Cole Parmer cat. no. U-06061-01, or equivalent. Discard after one use to eliminate possible contamination. Alternatively, use clean, 10-L carboy

5                                                      December 2005

 

with bottom delivery port (Ω”), Cole-Palmer cat. no. 06080-42, or equivalent; calibrate to 10.0 L and mark level with waterproof marker

  • Stir bar—Fisher cat. no. 14-513-66, or equivalent
  • Stir plate—Fisher cat. no. 11-510-49S, S50461HP, or equivalent
  • Hemacytometer—Neubauer type, Hausser Scientific, Horsham, PA, product no. 3200 or 1475, or equivalent
  • Hemacytometer coverslip—Hausser Scientific, product no. 5000 (for hemacytometer
  1. 3200) or 1461 (for hemacytometer cat. no 1475), or equivalent
  • Lens paper without silicone—Fisher cat. no. 11-995, or equivalent
  • Polystyrene or polypropylene conical tubes with screw caps—15- and 50-mL
  • Equipment required for enumeration of spiking suspensions using membrane filters
    • Glass microanalysis filter holder—25-mm-diameter, with fritted glass

support, Fisher cat. no. 09-753E, or equivalent. Replace stopper with size 8, one-hole rubber stopper, Fisher Cat. No. 14-135M, or equivalent.

  • Three-port vacuum filtration manifold and vacuum source—Fisher Cat. No. 09-753-39A, or equivalent
  • Cellulose acetate support membrane—1.2-µm-pore-size, 25-mm-

diameter, Fisher cat. no. A12SP02500, or equivalent

  • Polycarbonate track-etch hydrophilic membrane filter—1-µm-pore-size, 25-mm-diameter, Fisher cat. no. K10CP02500, or equivalent
  • 100 ◊ 15 mm polystyrene petri dishes (bottoms only)
  • 60 ◊ 15 mm polystyrene petri dishes
  • Glass microscope slides—1 in. ◊ 3 in or 2 in. ◊ 3
  • Coverslips—25 mm2
  • Immunomagnetic separation (IMS) apparatus
    • Sample mixer—Dynal Inc., Lake Success, NY, cat. 947.01, or equivalent
    • Magnetic particle concentrator for 10-mL test tubes—Dynal MPC®-1 , cat. no. 120.01 or MPC®-6, cat. No 120.02, or equivalent
    • Magnetic particle concentrator for microcentrifuge tubes—Dynal MPC®-M, cat.

120.09 (no longer available); Dynal MPC®-S, cat. no. 120.20, or equivalent

  • Flat-sided sample tubes—16 ◊ 125 mm Leighton-type tubes with 60 ◊ 10 mm flat-sided magnetic capture area, Dynal L10, cat. no. 740.03, or equivalent
  • Powder-free latex gloves—Fisher cat no. 113945B, or equivalent
  • Graduated cylinders, autoclavable—10-, 100-, and 1000-mL
  • Centrifuges
    • Centrifuge capable of accepting 15- to 250-mL conical centrifuge tubes and achieving

1500 ◊ G—International Equipment Company, Needham Heights, MA, Centrifuge Size 2, Model K with swinging bucket, or equivalent

  • Centrifuge tubes—Conical, graduated, 1.5-, 50-, and 250-mL
  • Microscope
    • Epifluorescence/differential interference contrast (DIC) with stage and ocular

micrometers and 20X (N.A.=0.4) to 100X (N.A.=1.3) objectives—Zeiss™ Axioskop, Olympus™ BH, or equivalent. Hoffman Modulation Contrast optics may be equivalent.

December 2005                                         6

 

  • Excitation/band-pass filters for immunofluorescence assay (FA)—Zeiss™ 487909 or

equivalent, including, 450- to 490-nm exciter filter, 510-nm dicroic beam-splitting mirror, and 515- to 520-nm barrier or suppression filter

 

Microscope model

 

Fluoro-chrome

 

Excitation filter (nm)

Dichroic beam- splitting

mirror (nm)

Barrier or suppression filter (nm) Chroma catalog number
Zeiss™ – Axioskop  

DAPI (UV)

 

340-380

 

400

 

420

 

CZ902

Zeiss™ -IM35 DAPI (UV) 340-380 400 420 CZ702
 

Olympus™ BH

DAPI (UV) 340-380 400 420 11000
Filter holder 91002
 

Olympus™ BX

DAPI (UV) 340-380 400 420 11000
Filter holder 91008
 

Olympus™ IMT2

DAPI (UV) 340-380 400 420 11000
Filter holder 91003

 

  • Excitation/band-pass filters for DAPI—Filters cited below (Chroma Technology, Brattleboro, VT), or equivalent
  • Ancillary equipment for microscopy
6.10.1 Well slides— Spot-On well slides, Dynal cat. no. 740.04; treated, 12-mm diameter well
slides, Meridian Diagnostics Inc., Cincinnati, OH, cat. no. R2206; or equivalent
6.10.2 Glass coverslips—22 ◊ 50 mm
6.10.3 Nonfluorescing immersion oil—Type FF, Cargille cat. no. 16212, or equivalent
6.10.4 Micropipette, adjustable:        0- to 10-µL with 0- to 10-µL tips
10- to 100-µL, with 10- to 200-µL tips

100- to 1000-µL with 100- to 1000-µL tips

6.10.5 Forceps—Splinter, fine tip
6.10.6 Forceps—Blunt-end
6.10.7 Desiccant—Drierite™ Absorbent, Fisher cat. no. 07-577-1A, or equivalent
6.10.8 Humid chamber—A tightly sealed plastic container containing damp paper towels on top
of which the slides are placed
6.11 Pipettes—Glass or plastic
6.11.1 5-, 10-, and 25-mL
6.11.2 Pasteur, disposable
6.12 Balances
6.12.1 Analytical—Capable of weighing 0.1 mg
6.12.2 Top loading—Capable of weighing 10 mg
  • pH meter
  • Incubator—Fisher Scientific Isotemp™, or equivalent
  • Vortex mixer—Fisons Whirlmixer, or equivalent
  • Vacuum source—Capable of maintaining 25 in. Hg, equipped with shutoff valve and vacuum gauge
  • Miscellaneous labware and supplies
    • Test tubes and rack
  • December 2005

 

  • Flasks—Suction, Erlenmeyer, and volumetric, various sizes

6.17.3   Beakers—Glass or plastic, 5-, 10-, 50-, 100-, 500-, 1000-, and 2000-mL

6.17.4   Lint-free tissues

  • 10- to 15-L graduated container—Fisher cat. no. 02-961-50B, or equivalent; calibrate to 9.0, 9.5, 10.0, 10.5, and 11.0 L and mark levels with waterproof marker

6.19     Filters for filter-sterilizing reagents—Sterile Acrodisc, 0.45 µm, Pall Corporation, cat. no. 4184, or equivalent

7.0                   Reagents and Standards

  • Reagents for adjusting pH
    • Sodium hydroxide (NaOH)—ACS reagent grade, 6.0 N and 1.0 N in reagent water
  • Hydrochloric acid (HCl)—ACS reagent grade, 6.0 N, 0 N, and 0.1 N in reagent water

NOTE:  Due to the low volumes of pH-adjusting reagents used in this method, and the

impact that changes in pH have on the immunofluorescence assay, the laboratory must purchase standards at the required normality directly from a vendor. Normality must not be adjusted by the laboratory.

  • Solvents—Acetone, glycerol, ethanol, and methanol, ACS reagent grade
  • Reagent water—Water in which oocysts and cysts and interfering materials and substances, including magnetic minerals, are not detected by this method. See Reference 20.8 (Section 9020) for reagent water
  • Reagents for eluting filters

NOTE: Laboratories should store prepared eluting solution for no more than 1 week or when noticeably turbid, whichever comes sooner.

  • Reagents for eluting Envirochek™ and Envirochek™ HV sampling capsules (Section 6.2.2)
    • Laureth-12—PPG Industries, Gurnee, IL, no. 06194, or equivalent.

Store Laureth-12 as a 10% solution in reagent water. Weigh 10 g of Laureth-12 and dissolve using a microwave or hot plate in 90 mL of reagent water. Dispense 10-mL aliquots into sterile vials and store at room temperature for up to 2 months, or in the freezer for up to a year.

  • 1 M Tris, pH 7.4—Dissolve 121.1 g Tris (Fisher cat. no. BP152) in 700

mL of reagent water and adjust pH to 7.4 with 1 N HCl or NaOH. Dilute to a final 1000 mL with reagent water and adjust the final pH. Filter- sterilize through a 0.2-µm membrane into a sterile plastic container and store at room temperature. Alternatively, use prepared TRIS, Sigma T6066 or equivalent.

  • 5 M EDTA, 2 Na, pH 8.0—Dissolve 186.1 g ethylenediamine

tetraacetic acid, disodium salt dihydrate (Fisher cat. no. S311) in 800 mL of reagent water and adjust pH to 8.0 with 6.0 N HCl or NaOH. Dilute to a final volume of 1000 mL with reagent water and adjust to pH 8.0 with

1.0 N HCl or NaOH. Alternatively, use prepared EDTA, Sigma E5134 or equivalent.

  • Antifoam A—Sigma Chemical Co. cat. no. A5758, or equivalent
  • Preparation of elution buffer solution—Add the contents of a pre- prepared Laureth-12 vial (Section 7.4.1.1) to a 1000-mL graduated

December 2005                                         8

 

cylinder. Rinse the vial several times to ensure the transfer of the detergent to the cylinder. Add 10 mL of Tris solution (Section 7.4.1.2), 2 mL of EDTA solution (Section 7.4.1.3), and 150 µL Antifoam A (Section 7.4.1.4). Dilute to 1000 mL with reagent water.

  • Reagents for eluting Filta-Max® foam filters (Section 2.3)
    • Phosphate buffered saline (PBS), pH 7.4—Sigma Chemical Co. cat.

P-3813, or equivalent. Alternately, prepare PBS by adding the following to 1 L of reagent water: 8 g NaCl; 0.2 g KCl; 1.15 g Na2HPO4, anhydrous; and 0.2 g KH2PO4.

  • Tween® 20 —Sigma Chemical cat. no. P-7949, or equivalent
  • High-vacuum grease—BDH/Merck. cat. no. 636082B, or equivalent
  • Preparation of PBST elution buffer. Add 100 µL of Tween® 20 to

prepared PBS (Section 7.4.2.1). Alternatively, add the contents of one packet of PBS to 1.0 L of reagent water. Dissolve by stirring for 30 minutes. Add 100 µL of Tween® 20 . Mix by stirring for 5 minutes.

  • Reagents for Portable Continuous-Flow Centrifuge (Section 2.4)
    • Sodium dodecyl sulfate—Sigma Chemical Co. cat. no. 71730 or equivalent
    • TWEEN 80— Sigma Chemical cat. no. P1754 or equivalent
    • Antifoam A—Sigma Chemical Co. cat. no. A5758, or equivalent
    • Preparation of concentrated elution buffer. Add above reagents to obtain

a final concentration of 1% sodium dodecyl sulfate, 0.01% TWEEN 80, and 0.001% Antifoam A in concentrated sample volume of ~250mL

  • Reagents for immunomagnetic separation (IMS)—Dynabeads® GC-Combo, Dynal cat. nos. 730.02/730.12, or equivalent
  • Direct antibody labeling reagents for detection of oocysts and cysts. Store reagents between 1°C and 10°C and return promptly to this temperature after each use. Do not allow any of the reagents to freeze. The reagents should be protected from exposure to light. Diluted, unused working reagents should be discarded after 48 hours. Discard reagents after the expiration date is reached. The labeling reagents in Sections 7.6.1-7.6.3 have been approved for use with this
    • MeriFluor® Cryptosporidium/Giardia, Meridian Diagnostics cat. no. 250050, Cincinnati, OH, or equivalent
    • Aqua-Glo™ G/C Direct FL, Waterborne cat. no. A100FLR, New Orleans, LA, or

equivalent

  • Crypt-a-Glo™ and Giardi-a-Glo™, Waterborne cat. nos. A400FLR and A300FLR, respectively, New Orleans, LA, or equivalent
  • EasyStain™C&G, BTF Pty Limited, Sydney, Australia or equivalent

NOTE:  If a laboratory will use multiple types of labeling reagents, the laboratory  must

demonstrate acceptable performance through an initial precision and recovery test (Section 9.4) for each type, and must perform positive and negative staining controls for each batch of slides stained using each product. However, the laboratory is not required to analyze additional ongoing precision and recovery samples or method blank samples for each type. The performance of each labeling reagent used also should be monitored in each source water type.

  • Diluent for labeling reagents—Phosphate buffered saline (PBS) (Section 4.2).

9                                                      December 2005

 

  • 4′,6-diamidino-2-phenylindole (DAPI) stain—Sigma Chemical Co. cat. no. D9542, or equivalent
    • Stock solution—Dissolve 2 mg/mL DAPI in absolute methanol. Prepare volume

consistent with minimum use. Store between 1°C and 10°C in the dark. Do not allow to freeze. Discard unused solution when positive staining control fails or after specified time determined by laboratory.

  • Staining solution—Follow antibody kit manufacturer’s instructions. Add 10 µL of 2

mg/mL DAPI stock solution to 50 mL of PBS for use with Aqua-Glo™ G/C Direct FL or MeriFluor® Cryptosporidium/Giardia. Add 50 µL of 2 mg/mL DAPI stock solution to 50 mL of PBS for use with EasyStain™. Prepare working solution daily and store between 1°C and 10°C (do not allow to freeze). DAPI is light sensitive; therefore, store  in the dark except when staining. The DAPI concentration may be increased if fading/diffusion of DAPI staining is encountered, but the staining solution must be tested first on expendable environmental samples to confirm that staining intensity is appropriate.

  • Mounting medium
    • DABCO/glycerol mounting medium (2%)—Dissolve 2 g of DABCO (Sigma Chemical

Co. cat no. D-2522, or equivalent) in 95 mL of warm glycerol/PBS (60% glycerol, 40% PBS). After the DABCO has dissolved completely, adjust the solution volume to 100 mL by adding an appropriate volume of glycerol/PBS solution. Alternately, dissolve the DABCO in 40 mL of PBS, then add azide (1 mL of 100X, or 10% solution), then 60 mL of glycerol.

  • Mounting medium supplied with MeriFluor® Cryptosporidium/Giardia, Meridian Diagnostics cat. 250050, or equivalent (Section 7.6.1)
  • Mounting medium supplied with Aqua-Glo™ G/C Direct FL kit, Waterborne cat.

A100FLR, cat. no. M101, or equivalent (Section 7.6.2)

  • Mounting medium supplied with EasyStain™C&G, BTF Pty Limited or equivalent (Section 6.4)
  • Elvanol or equivalent permanent, non-fade archiving mounting medium
  • Clear fingernail polish or clear fixative, PGC Scientifics, Gaithersburg, MD, cat. no. 60-4890-00, or equivalent
  • Oocyst and cyst suspensions for spiking
    • Enumerated spiking suspensions prepared by flow cytometer—not formalin
      • Live, flow cytometer–sorted oocysts and cysts—Wisconsin State

Laboratory of Hygiene Flow Cytometry Unit ([608] 224-6260), or equivalent

  • Irradiated, flow cytometer–sorted oocysts and cysts—flow

cytometer–sorted oocysts and cysts—BTF EasySeed™ (contact@btfbio.com), or equivalent

  • Materials for manual enumeration of spiking suspensions
    • Purified Cryptosporidium oocyst stock suspension for manual

enumeration—not formalin-fixed: Sterling Parasitology Laboratory, University of Arizona, Tucson, or equivalent

  • Purified Giardia cyst stock suspension for manual enumeration—not

formalin-fixed: Waterborne, Inc., New Orleans, LA; Hyperion Research, Medicine Hat, Alberta, Canada; or equivalent

December 2005                                        10

 

  • Tween® 20 , 0.01%—Dissolve 1.0 mL of a 10% solution of Tween® 20 in 1 L of reagent water
  • Storage procedure—Store oocyst and cyst suspensions between 1°C and 10°C, until

ready to use; do not allow to freeze

  • Additional reagents for enumeration of spiking suspensions using membrane filtration (Section 11.3.6)—Sigmacote® Sigma Company Product No. SL-2, or equivalent

8.0                   Sample Collection and Storage

  • Sample collection, shipment, and receipt
    • Sample collection. Samples are collected as bulk samples and shipped to the laboratory

on ice for processing through the entire method, or are filtered in the field and shipped to the laboratory on ice for processing from elution (Section 12.2.6) onward.

  • Sample shipment. Ambient water samples are dynamic environments and, depending on sample constituents and environmental conditions, Cryptosporidium oocysts or Giardia

cysts present in a sample can degrade, potentially biasing analytical results. Samples

should be chilled to reduce biological activity, and preserve the state of source water samples between collection and analysis. Samples analyzed by an off-site laboratory should be shipped on ice via overnight service on the day they are collected.

NOTE:  See transportation precautions in Section 5.5.

  • If samples are collected early in the day, chill samples by storing in a

refrigerator between 1°C and 10°C or pre-icing the sample in a cooler. If the sample is pre-iced before shipping, replace with fresh ice immediately before shipment.

  • If samples are collected later in the day, these samples may be chilled

overnight in a refrigerator between 1°C and 10°C. This should be considered for bulk water samples that will be shipped off-site, as this minimizes the potential for water samples collected during the summer to melt the ice in which they are packed and arrive at the laboratory at

>20°C.

  • If samples are shipped after collection at >20°C with no chilling, the sample will not maintain the temperature during shipment at #20°C.
  • Public water systems shipping samples to off-site laboratories for analysis

should include in the shipping container a means for monitoring the temperature of the sample during shipping to verify that the sample did not freeze or exceed 20°C. Suggested approaches for monitoring sample temperature during shipping are discussed in Section 8.1.4.

  • Sample receipt. Upon receipt, the laboratory must record the sample temperature. Samples that were not collected the same day they were received, and that are received at

>20°C or frozen, or samples that the laboratory has determined exceeded >20°C or froze

during shipment, must be rejected. After receipt, samples must be stored at the laboratory between 1°C and 10°C, and not frozen, until processed.

  • Suggestions on measuring sample temperature. Given the importance of maintaining

sample temperatures for Cryptosporidium and Giardia determination, laboratories performing analyses using this method must establish acceptance criteria for receipt of samples transported to their laboratory. Several options are available to measure sample temperature upon receipt at the laboratory and, in some cases, during shipment:

  • Temperature sample. One option, for filtered samples only (not for 10-L bulk samples), is for the sampler to fill a small, inexpensive sample bottle

11                                                      December 2005

 

with water and pack this “temperature sample” next to the filtered sample. The temperature of this extra sample volume is measured upon receipt to estimate the temperature of the filter. Temperature sample bottles are not appropriate for use with bulk samples because of the potential effect that the difference in sample volume may have in temperature equilibration in the sample cooler. Example product: Cole Parmer cat. no. U-06252-20.

  • Thermometer vial. A similar option is to use a thermometer that is

securely housed in a liquid-filled vial. Unlike temperature samples, the laboratory does not need to perform an additional step to monitor the temperature of the vial upon receipt, but instead just needs to read the thermometer. The thermometer vial is appropriate for use with filtered samples not bulk samples. Example product: Eagle-Picher Sentry Temperature Vial 3TR-40CS-F or 3TR-40CS.

  • Measures the sample temperature during shipment and upon

receipt.  An iButton is a small, waterproof device that contains a computer chip that can be programmed to record temperature at different time intervals.  The information is then downloaded from the iButton  onto a computer. The iButton should be placed in a temperature sample, rather than placed loose in the cooler, or attached to the sample container. This option is appropriate for use with both filtered and bulk samples.

Information on Thermocron® iButtons is available from

http://www.ibutton.com/. Distributors include http://www.pointsix.com/, http://www.rdsdistributing.com, and http://www.scigiene.com/.

  • Stick-on temperature strips. Another option is for the laboratory to

apply a stick-on temperature strip to the outside of the sample container upon receipt at the laboratory. This option does not measure temperature as precisely as the other options, but provides an indication of sample temperature to verify that the sample temperature is acceptable. This option is appropriate for use with both filtered and bulk samples. Example product: Cole Parmer cat. no. U-90316-00.

  • Infrared thermometers. A final option is to measure the temperature of

the surface of the sample container or filter using an infrared  thermometer. The thermometer is pointed at the sample, and measures the temperature without coming in contact with the sample volume. This option is appropriate for use with both filtered and bulk samples. Example product: Cole Parmer cat. no. EW-39641-00.

As with other laboratory equipment, all temperature measurement devices must be calibrated routinely to ensure accurate measurements. See the EPA Manual for the Certification of Laboratories Analyzing Drinking Water (Reference 20.9) for more information.

  • Sample holding times. Samples must be processed or examined within each of the holding times specified in Sections 8.2.1 through 8.2.4. Sample processing should be completed as soon as possible by the laboratory. The laboratory should complete sample filtration, elution, concentration, purification, and staining the day the sample is received wherever possible. However, the laboratory is permitted to split up the sample processing steps if processing a sample completely in one day is not possible. If this is necessary, sample processing can be halted after filtration, application of the purified sample onto the slide, or staining. Table 1, in Section

21.0 provides a breakdown of the holding times for each set of steps. Sections 8.2.1 through 8.2.4 provide descriptions of these holding times.

December 2005                                        12

 

  • Sample collection and filtration. Sample elution must be initiated within 96 hours of

sample collection (if shipped to the laboratory as a bulk sample) or filtration (if filtered in the field).

  • Sample elution, concentration, and purification. The laboratory must complete

elution, concentration, and purification (Sections 12.2.6 through 13.3.3.11) in one work day. It is critical that these steps be completed in one work day to minimize the time that any target organisms present in the sample sit in eluate or concentrated matrix. This process ends with the application of the purified sample on the slide for drying.

  • The sample must be stained within 72 hours of application of the purified sample to the slide.
  • Although immunofluorescence assay (FA) and 4′,6-diamidino-2-

phenylindole (DAPI) and differential interference contrast (DIC) microscopy examination and characterization should be performed immediately after staining is complete, laboratories have up to 168 hours (7 days) from the completion of sample staining to perform the examination and verification of samples. However, if fading/diffusion of FITC or DAPI staining is noticed, the laboratory must reduce this holding time. In addition the laboratory may adjust the concentration of the DAPI staining solution (Sections 7.7.2) so that fading/diffusion does not occur.

  • Spiking suspension enumeration holding times. Flow-cytometer-sorted spiking suspensions (Sections 7.10.1 and 11.2) used for spiked quality control (QC) samples (Section 9) must be used within the expiration date noted on the suspension. Manually enumerated spiking suspensions must be used within 24 hours of enumeration of the spiking suspension if the hemacytometer chamber technique is used (Section 11.3.4); or within 24 hours of application of the spiking suspension to the slides if the well slide or membrane filter enumeration technique is used (Sections 11.3.5 and 11.3.6). Oocyst and cyst suspensions must be stored between 1°C and 10°C, until ready to use; do not allow to

9.0                   Quality Control

  • Each laboratory that uses this method is required to operate a formal quality assurance (QA) program that addresses and documents data quality, instrument and equipment maintenance and performance, reagent quality and performance, analyst training and certification, and records storage and retrieval. General requirements and recommendations for QA and quality control (QC) procedures for microbiology laboratories are provided in References 20.8, 20.9, 20.10. The minimum analytical requirements of this program consist of an initial demonstration of laboratory capability (IDC) through performance of the initial precision and recovery (IPR) test (Section 9.4), and ongoing demonstration of laboratory capability and method performance through the matrix spike (MS) test (Section 9.5.1), the method blank test (Section 9.6), the ongoing precision and recovery (OPR) test (Section 9.7), staining controls (Section 14.1 and 15.2.1), and analyst verification tests (Section 10.6). Laboratory performance is compared to established performance criteria to determine if the results of analyses meet the performance characteristics of the
    • A test of the microscope used for detection of oocysts and cysts is performed prior to examination of slides. This test is described in Section 0.
    • In recognition of advances that are occurring in analytical technology, the laboratory is

permitted to modify certain method procedures to improve recovery or lower the costs of measurements, provided that all required quality control (QC) tests are performed and all QC acceptance criteria are met. Method procedures that can be modified include front- end techniques, such as filtration or immunomagnetic separation (IMS). The laboratory  is not permitted to use an alternate determinative technique to replace immunofluorescence assay in this method (the use of different determinative techniques are considered to be different methods, rather than modified version of this method).

13                                                      December 2005

 

However, the laboratory is permitted to modify the immunofluorescence assay procedure, provided that all required QC tests are performed (Section 9.1.2.1) and all QC acceptance criteria are met (see guidance on the use of multiple labeling reagents in Section 7.6).

NOTE:  Method modifications should be considered only to improve method

performance, reduce cost, or reduce sample processing time. Method modifications that reduce cost or sample processing time, but that result in poorer method performance should not be used.

  • Method modification validation/equivalency demonstration requirements

9.1.2.1.1       Method modifications at a single laboratory. Each

time a modification is made to this method for use in a single laboratory, the laboratory must, at a minimum, validate the modification according to Tier 1 of EPA’s performance-based measurement system (PBMS) (Table

2) to demonstrate that the modification produces results equivalent or superior to results produced by this method as written. Briefly, each time a modification is made to this method, the laboratory is required to demonstrate acceptable modified method performance through the IPR test (Section 9.4). IPR results must meet the QC acceptance criteria in Tables 3 and 4 in Section 21.0, and should be comparable to previous results using the unmodified procedure. Although not required, the laboratory also should perform a matrix spike/matrix spike duplicate (MS/MSD) test to demonstrate the performance of the modified method in at least one real- world matrix before analyzing field samples using the modified method. The laboratory is required to perform MS samples using the modified method at the frequency noted in Section 9.1.8. If the modified method involves changes that cannot be adequately evaluated through these tests, additional tests may be required to demonstrate acceptability.

9.1.2.1.2       Method modifications for nationwide approval. If the

laboratory or a manufacturer seeks EPA approval of a method modification for nationwide use, the laboratory or manufacturer must, at a minimum, validate the modification according to Tier 2 of EPA’s PBMS (Table 2). Briefly, at least three laboratories must perform IPR tests (Section 9.4) and MS/MSD (Section 9.5) tests using the modified method, and all tests must meet the QC acceptance criteria specified in Tables 3 and 4 in Section

21.0. Upon nationwide approval, laboratories electing to use the modified method still must demonstrate acceptable performance in their own laboratory according to the requirements in Section 9.1.2.1.1. If the modified method involves changes that cannot be adequately evaluated through these tests, additional tests may be required to demonstrate acceptability.

  • The laboratory is required to maintain records of modifications made to this method. These records include the following, at a minimum:

December 2005                                        14

 

  • The names, titles, addresses, and telephone numbers of

the analyst(s) who performed the analyses and modification, and of the quality control officer who witnessed and will verify the analyses and modification.

  • A listing of the analyte(s) measured (Cryptosporidium and Giardia).
  • A narrative stating reason(s) for the
  • Results from all QC tests comparing the modified method to this method, including:
    • IPR (Section 4)
    • MS/MSD (Section 5)
    • Analysis of method blanks (Section 6)
  • Data that will allow an independent reviewer to validate

each determination by tracing the following processing and analysis steps leading to the final result:

  • Sample numbers and other identifiers
  • Source of spiking suspensions, as well as lot number and date received (Section 10)
  • Spike enumeration date and time
  • All spiking suspension enumeration counts and calculations (Section 0)
  • Sample spiking dates and times
  • Volume filtered (Section 2.5.2)
  • Filtration and elution dates and times
  • Pellet volume, resuspended concentrate volume, resuspended concentrate volume transferred to IMS, and all calculations required to verify the percent of concentrate examined (Section 2)
  • Purification completion dates and times (Section 13.3.3.11)
  • Staining completion dates and times (Section 14.10)
  • Staining control results (Section 2.1)
  • All required examination information (Section 15.2.2)
  • Examination completion dates and times (Section 15.2.4)
  • Analysis sequence/run chronology
  • Lot numbers of elution, IMS, and staining reagents
  • Copies of bench sheets, logbooks, and other recordings of raw data
  • Data system outputs, and other data to link the raw data to the results reported
  • The laboratory shall spike a separate sample aliquot from the same source to monitor

method performance. The frequency of the MS test is described in Section 9.1.8 and the procedures are described in Section 9.5.1.

  • Analysis of method blanks is required to demonstrate freedom from contamination. The

frequency of the analysis of method blanks is described in Section 9.1.7 and the procedures and criteria for analysis of a method blank are described in Section 9.6.

15                                                      December 2005

 

  • The laboratory shall, on an ongoing basis, demonstrate through analysis of the ongoing

precision and recovery (OPR) sample that the analysis system is in control. Frequency of OPR samples is described in Section 9.1.7 and the procedures are described in Section 9.7.

  • The laboratory shall maintain records to define the quality of data that are Development of accuracy statements is described in Sections 9.5.1.4 and 9.7.6.
  • The laboratory shall analyze one method blank (Section 9.6) and one OPR sample

(Section 9.7) each week (7 day or 168 hours time period which begins with processing the OPR) in which samples are analyzed if 20 or fewer field samples are analyzed during this period. The laboratory shall analyze one laboratory blank and one OPR sample for every 20 samples if more than 20 samples are analyzed in a one week (7 day or 168 hours) period.

  • The laboratory shall analyze MS samples (Section 9.5.1) at a minimum frequency of 1

MS sample per 20 field samples from each source analyzed. The laboratory should analyze an MS sample when samples are first received from a PWS for which the laboratory has never before analyzed samples to identify potential method performance issues with the matrix (Section 9.5.1; Tables 3 and 4). If an MS sample cannot be analyzed on the first sampling event, the first MS sample should be analyzed as soon as possible to identify potential method performance issues with the matrix.

  • Micropipette calibration
    • Micropipettes must be sent to the manufacturer for calibration annually. Alternately, a

qualified independent technician specializing in micropipette calibration can be used, or the calibration can be performed by the laboratory, provided the laboratory maintains a detailed procedure that can be evaluated by an independent auditor. Documentation on the precision of the recalibrated micropipette must be obtained from the manufacturer or technician.

  • Internal and external calibration records must be kept on file in the laboratory’s QA logbook.
  • If a micropipette calibration problem is suspected, the laboratory shall tare an empty

weighing boat on the analytical balance and pipette the following volumes of reagent water into the weigh boat using the pipette in question: 100% of the maximum dispensing capacity of the micropipette, 50% of the capacity, and 10% of the capacity. Ten replicates should be performed at each weight. Record the weight of the water (assume that 1.00 mL of reagent water weighs 1.00 g) and calculate the relative standard deviation (RSD) for each. If the weight of the reagent water is within 1% of the desired weight (mL) and the RSD of the replicates at each weight is within 1%, then the pipette remains acceptable for use.

  • If the weight of the reagent water is outside the acceptable limits, consult the

manufacturer’s instruction manual troubleshooting section and repeat steps described in Section 9.2.3. If problems with the pipette persist, the laboratory must send the pipette to the manufacturer for recalibration.

  • Microscope adjustment and calibration —Adjust the microscope as specified in Section 10.0. All of the requirements in Section 10.0 must be met prior to analysis of IPRs, method blanks, OPRs, field samples, and MS/MSDs.
  • Initial precision and recovery (IPR)—To establish the ability to demonstrate control over the analytical system and to generate acceptable precision and recovery, the laboratory shall perform the following operations:
    • Using the spiking procedure in Section 11.4 and enumerated spiking suspensions (Section 7.10.1 or Section 11.3), spike, filter, elute, concentrate, separate (purify), stain,

December 2005                                        16

 

and examine the four reagent water samples spiked with ~100-500 oocysts and ~100-500 cysts.

  • The laboratory is permitted to analyze the four spiked reagent samples on

the same day or on as many as four different days (provided that the spiked reagent samples are analyzed consecutively), and also may use different analysts and/or reagent lots for each sample (however, the procedures used for all analyses must be identical). Laboratories should note that the variability of four measurements performed on multiple days or using multiple analysts or reagent lots may be greater than the variability of measurements performed on the same day with the same analysts and reagent lots. As a result, the laboratory is at a greater risk of generating unacceptable IPR results if the test is performed across multiple days, analysts, and /or reagent lots.

  • If more than one modification will be used for filtration and/or separation

of samples, a separate set of IPR samples must be prepared for each modification.

  • The set of four IPR samples must be accompanied by analysis of an acceptable method blank (Section 6).
  • For each organism, calculate the percent recovery (R) using the following equation:

     N   

R =    100 x

T

where:

R = the percent recovery

N = the number of oocysts or cysts counted T = the number of oocysts or cysts spiked

This calculation assumes that the total volume spiked was processed and examined.

  • Using percent recovery (R) of the four analyses, calculate the mean percent recovery and the relative standard deviation (RSD) of the recoveries for Cryptosporidium and for

Giardia. The RSD is the standard deviation divided by the mean, times 100.

  • Compare the mean and RSD to the corresponding method performance acceptance

criteria for initial precision and recovery in Tables 3 and 4 in Section 21.0. If the mean and RSD for recovery meet the acceptance criteria, system performance is acceptable  and analysis of blanks and samples may begin. If the mean or RSD falls outside the range for recovery, system performance is unacceptable. In this event, trouble-shoot the problem by starting at the end of the method (see guidance in Section 9.7.5), correct the problem and repeat the IPR test (Section 9.4.1).

  • Examine and document the IPR slides following the procedure in Section 15.0. The first

three Cryptosporidium oocysts and first three Giardia cysts identified in each IPR sample must be characterized (size, shape, DAPI category, and DIC category) and documented on the examination form, as well as any additional comments on organisms appearance, if notable.

  • Using 200X to 400X magnification, more than 50% of the oocysts or cysts must appear

undamaged and morphologically intact; otherwise, the organisms in the spiking suspension may be of unacceptable quality or the analytical process may be damaging the organisms. If the quality of the organisms on the IPR test slides is unacceptable, examine the spiking suspension organisms directly (by centrifuging, if possible, to concentrate the organisms in a volume that can be applied directly to a slide). If the

17                                                      December 2005

 

unprocessed organisms appear undamaged and morphologically intact under DIC, determine the step or reagent that is causing damage to the organisms. Correct the problem (see Section 9.7.5) and repeat the IPR test.

  • Matrix spike (MS) and matrix spike duplicate (MSD)
    • Matrix spike— The laboratory shall spike and analyze a separate field sample aliquot to

determine the effect of the matrix on the method’s oocyst and cyst recovery. The MS and field sample must be that was collected from the same sampling location as split samples or as samples sequentially collected immediately after one another. The MS sample volume analyzed must be within 10% of the field sample volume. The MS shall be analyzed according to the frequency in Section 9.1.8.

  • Analyze an unspiked field sample according to the procedures in Sections

12.0 to 15.0. Using the spiking procedure in Section 11.4 and enumerated spiking suspensions (Section 7.10.1 or Section 11.3), spike, filter, elute, concentrate, separate (purify), stain, and examine a second field sample aliquot with a similar number of organisms as that used in the IPR or OPR tests (Sections 9.4 and 9.7).

  • For each organism, calculate the percent recovery (R) using the following equation.

R =     100 x

Nsp – Ns T

where

R is the percent recovery

Nsp is the number of oocysts or cysts counted in the spiked sample Ns is the number of oocysts or cysts counted in the unspiked sample

T is the true value of the oocysts or cysts spiked

  • Compare the recovery for each organism with the acceptance criteria in Tables 3 and 4 in Section 0.

NOTE:  Some sample matrices may prevent the acceptance criteria in Tables 3 and 4

from being met. An assessment of the distribution of MS recoveries across 430 MS samples from 87 sites during the ICR Supplemental Surveys is provided in Table 5.

  • As part of the QA program for the laboratory, method precision for

samples should be assessed and records maintained. After the analysis of five samples, the laboratory should calculate the mean percent recovery

(P) and the standard deviation of the percent recovery (sr). Express the precision assessment as a percent recovery interval from P ! 2 sr to P + 2 sr for each matrix. For example, if P = 80% and sr = 30%, the accuracy interval is expressed as 20% to 140%. The precision assessment should be updated regularly across all MS samples and stratified by MS samples for each source.

  • Matrix spike duplicate—MSD analysis is required as part of Tier 2 or nationwide

approval of a modified version of this method to demonstrate that the modified version of this method produces results equal or superior to results produced by the method as written (Section 9.1.2.1.2). At the same time the laboratory spikes and analyzes the second field sample aliquot in Section 9.5.1.1, the laboratory shall spike and analyze a third, identical field sample aliquot.

December 2005                                        18

 

NOTE: Matrix spike duplicate samples are only required for Tier 2 validation studies. They are recommended for Tier 1 validation, but not required.

  • For each organism, calculate the percent recovery (R) using the equation in Section 5.1.2.
  • Calculate the mean of the number of oocysts or cysts in the MS and MSD

(Xmean) (= [MS+MSD]/2).

  • Calculate the relative percent difference (RPD) of the recoveries using the following equation:

RPD =      100 x

| NMS – NMSD | XMEAN

where

RPD is the relative percent difference

NMS is the number of oocysts or cysts counted in the MS NMSD is the number of oocysts or cysts counted in the MSD

Xmean is the mean number of oocysts or cysts counted in the MS and MSD

  • Compare the mean MS/MSD recovery and RPD with the acceptance criteria in Tables 3 and 4 in Section 21.0 for each
  • Method blank (negative control sample, laboratory blank)—Reagent water blanks are routinely

analyzed to demonstrate freedom from contamination. Analyze the blank immediately after analysis of the IPR test (Section 9.4) and OPR test (Section 9.7) and prior to analysis of samples for the week to demonstrate freedom from contamination.

  • Filter, elute, concentrate, separate (purify), stain, and examine at least one reagent water method blank per week (Section 9.1.7) according to the procedures in Sections 12.0 to

15.0. A method blank must be analyzed each week (7 day or 168 hours time period that

begins with processing the OPR) in which samples are analyzed if 20 or fewer field samples are analyzed during this period. If more than 20 samples are analyzed in a week (7 days or 168 hours), process and analyze one reagent water method blank for every 20 samples.

  • Actions
    • If Cryptosporidium oocysts, Giardia cysts, or potentially interfering

organisms or materials that may be misidentified as oocysts or cysts are not found in the method blank, the method blank test is acceptable and analysis of samples may proceed.

  • If Cryptosporidium oocysts, Giardia cysts (as defined in Section 3), or

any potentially interfering organism or materials that may be misidentified as oocysts or cysts are found in the method blank, the method blank test is unacceptable. Any field sample in a batch associated with an unacceptable method blank is assumed to be contaminated and should be recollected. Analysis of additional samples is halted until the source of contamination is eliminated, the method blank test is performed again, and no evidence of contamination is detected.

  • Ongoing precision and recovery (OPR; positive control sample; laboratory control sample)—Using the spiking procedure in Section 11.4 and enumerated spiking suspensions (Section 7.10.1 or Section 11.3), filter, elute, concentrate, separate (purify), stain, and examine at least one reagent water sample spiked with ~100 to 500 oocysts and ~100 to 500 cysts each week

19                                                      December 2005

 

to verify all performance criteria. The laboratory must analyze one OPR sample for every 20 samples if more than 20 samples are analyzed in a week. If multiple method variations are used, separate OPR samples must be prepared for each method variation. Adjustment and/or recalibration of the analytical system shall be performed until all performance criteria are met. Only after all performance criteria are met should samples be analyzed.

  • Examine the slide from the OPR prior to analysis of samples from the same
    • Using 200X to 400X magnification, more than 50% of the oocysts or

cysts must appear undamaged and morphologically intact; otherwise, the organisms in the spiking suspension may be of unacceptable quality or the analytical process may be damaging the organisms. Examine the spiking suspension organisms directly (by centrifuging, if possible, to concentrate the organisms in a volume that can be applied directly to a slide). If the organisms appear undamaged and morphologically intact under DIC, determine the step or reagent that is causing damage to the organisms. Correct the problem and repeat the OPR test.

  • Identify and enumerate each organism using epifluorescence

The first three Cryptosporidium oocysts and three Giardia cysts identified in the OPR sample must be examined using FITC, DAPI, and DIC, as per Section 15.2, and the detailed characteristics (size, shape, DAPI category, and DIC category) reported on the Cryptosporidium and Giardia report form, as well as any additional comments on organism appearance, if notable.

  • For each organism, calculate the percent recovery (R) using the following equation:

     N   

R =    100 x

T

where:

R = the percent recovery

N = the number of oocysts or cysts detected T = the number of oocysts or cysts spiked

  • Compare the recovery with the acceptance criteria for ongoing precision and recovery in Tables 3 and 4 in Section 0.
  • Actions
    • If the recoveries for Cryptosporidium and Giardia meet the acceptance

criteria, system performance is acceptable and analysis of samples may proceed.

  • If the recovery for Cryptosporidium or Giardia falls outside of the

criteria, system performance is unacceptable. Any sample in a batch associated with an unacceptable OPR sample is unacceptable. Analysis of additional samples is halted until the analytical system is brought under control. Troubleshoot the problem using the procedures at Section 9.7.5 as a guide. After assessing the issue, perform another OPR test and verify that Cryptosporidium and Giardia recoveries meet the acceptance  criteria.

  • If an OPR sample has failed, and the cause of the failure is not known,

the laboratory generally should identify the problem working backward in the analytical process from the microscopic examination to filtration.

December 2005                                        20

 

  • Quality of spiked organisms. Examine the spiking suspension organisms

directly (by centrifuging, if possible, to concentrate the organisms in a volume that can be applied directly to a slide). If the organisms appear damaged under DIC, obtain fresh spiking materials. If the organisms appear undamaged and morphologically intact, determined whether the problem is associated with the microscope system or antibody stain (Section 9.7.5.2).

  • Microscope system and antibody stain: To determine if the failure of

the OPR test is due to changes in the microscope or problems with the antibody stain, re-examine the positive staining control (Section 15.2.1), check Köhler illumination, and check the fluorescence of the fluorescein- labeled monoclonal antibodies (Mabs) and 4′,6-diamidino-2-phenylindole (DAPI). If results are unacceptable, re-examine a previously-prepared positive staining control to determine whether the problem is associated with the microscope or the antibody stain.

  • Separation (purification) system: To determine if the failure of the

OPR test is attributable to the separation system, check system performance by spiking a 10-mL volume of reagent water with ~100 – 500 oocysts and cysts and processing the sample through the IMS, staining, and examination procedures in Sections 13.3 through 15.0. Recoveries should be greater than 70%.

  • Filtration/elution/concentration system: If the failure of the OPR test is

attributable to the filtration/elution/concentration system, check system performance by processing spiked reagent water according to the procedures in Section 12.2 through 13.2.2, and filter, stain, and examine the sample concentrate according to Section 11.3.6.

  • The laboratory should add results that pass the specifications in Section 9.7.3 to initial

and previous ongoing data and update the QC chart to form a graphic representation of continued laboratory performance. The laboratory should develop a statement of laboratory accuracy (reagent water, raw surface water) by calculating the mean percent recovery (R) and the standard deviation of percent recovery (sr). Express the accuracy as a recovery interval from R ! 2 sr to R + 2 sr. For example, if R = 95% and sr = 25%, the accuracy is 45% to 145%.

  • The laboratory should periodically analyze an external QC sample, such as a performance evaluation or standard reference material, when available. The laboratory also should periodically participate in interlaboratory comparison studies using the
  • The specifications contained in this method can be met if the analytical system is under control. The standards used for initial (Section 9.4) and ongoing (Section 9.7) precision and recovery should be identical, so that the most precise results will be obtained. The microscope in particular will provide the most reproducible results if dedicated to the settings and conditions required for the determination of Cryptosporidium and Giardia by this
  • Depending on specific program requirements, field replicates may be collected to determine the precision of the sampling technique, and duplicate spiked samples may be required to determine the precision of the

10.0            Microscope Calibration and Analyst Verification

  • In a room capable of being darkened to near-complete darkness, assemble the microscope, all filters, and attachments. The microscope should be placed on a solid surface free from vibration. Adequate workspace should be provided on either side of the microscope for taking notes and placement of slides and ancillary

21                                                      December 2005

 

  • Using the manuals provided with the microscope, all analysts must familiarize themselves with operation of the
  • Microscope adjustment and calibration (adapted from Reference 10)
    • Preparations for adjustment
      • The microscopy portion of this procedure depends upon proper alignment

and adjustment of very sophisticated optics. Without proper alignment and adjustment, the microscope will not function at maximal efficiency, and reliable identification and enumeration of oocysts and cysts will not be possible. Consequently, it is imperative that all portions of the microscope from the light sources to the oculars are properly adjusted.

  • While microscopes from various vendors are configured somewhat

differently, they all operate on the same general physical principles. Therefore, slight deviations or adjustments may be required to make the procedures below work for a particular instrument.

  • The sections below assume that the mercury bulb has not exceeded time

limits of operation, that the lamp socket is connected to the lamp house, and that the condenser is adjusted to produce Köhler illumination.

  • Persons with astigmatism should always wear contact lenses or glasses when using the

CAUTION:      In the procedures below, do not touch the quartz portion of the mercury

bulb with your bare fingers. Finger oils can cause rapid degradation of the quartz and premature failure of the bulb.

 

WARNING:     Never look at the ultraviolet (UV) light from the mercury lamp, lamp

house, or the UV image without a barrier filter in place. UV radiation can cause serious eye damage.

  • Epifluorescent mercury bulb adjustment: The purpose of this procedure is to ensure even

field illumination. This procedure must be followed when the microscope is first used, when replacing bulbs, and if problems such as diminished fluorescence or uneven field illumination are experienced.

  • Remove the diffuser lens between the lamp and microscope or swing it out of the transmitted light
  • Using a prepared microscope slide, adjust the focus so the image in the

oculars is sharply defined.

  • Replace the slide with a business card or a piece of lens
  • Close the field diaphragm (iris diaphragm in the microscope base) so only

a small point of light is visible on the card. This dot of light indicates the location of the center of the field of view.

  • Mount the mercury lamp house on the microscope without the UV diffuser lens in place and turn on the mercury
  • Remove the objective in the light path from the A primary

(brighter) and secondary image (dimmer) of the mercury bulb arc should appear on the card after focusing the image with the appropriate adjustment.

December 2005                                        22

 

  • Using the lamp house adjustments, adjust the primary and secondary

mercury bulb images so they are side by side (parallel to each other) with the transmitted light dot in between them.

  • Reattach the objective to the
  • Insert the diffuser lens into the light path between the mercury lamp house and the
  • Turn off the transmitted light and replace the card with a slide of

fluorescent material. Check the field for even fluorescent illumination. Adjustment of the diffuser lens probably will be required. Additional slight adjustments as in Section 10.3.2.7 above may be required.

  • Maintain a log of the number of hours the UV bulb has been used. Never

use the bulb for longer than it has been rated. Fifty-watt bulbs should not be used longer than 100 hours; 100-watt bulbs should not be used longer than 200 hours.

  • Transmitted bulb adjustment: The purpose of this procedure is to center the filament and

ensure even field illumination. This procedure must be followed when the bulb is changed.

  • Remove the diffuser lens between the lamp and microscope or swing it out of the transmitted light
  • Using a prepared microscope slide and a 40X (or similar) objective,

adjust the focus so the image in the oculars is sharply defined.

  • Without the ocular or Bertrand optics in place, view the pupil and filament image at the bottom of the
  • Focus the lamp filament image with the appropriate adjustment on the

lamp house.

  • Similarly, center the lamp filament image within the pupil with the appropriate adjustment(s) on the lamp
  • Insert the diffuser lens into the light path between the transmitted lamp

house and the microscope.

  • Adjustment of the interpupillary distance and oculars for each eye: These adjustments

are necessary so that eye strain is reduced to a minimum, and must be made for each individual using the microscope. Section 10.3.4.2 assumes use of a microscope with both oculars adjustable; Section 10.3.4.3 assumes use of a microscope with a single adjustable ocular. The procedure must be followed each time an analyst uses the  microscope.

  • Interpupillary distance
    • Place a prepared slide on the microscope stage, turn on

the transmitted light, and focus the specimen image using the coarse and fine adjustment knobs.

  • Using both hands, move the oculars closer together or

farther apart until a single circle of light is observed while looking through the oculars with both eyes. Note interpupillary distance.

  • Ocular adjustment for microscopes capable of viewing a photographic

frame through the viewing binoculars: This procedure assumes both oculars are adjustable.

  • Place a card between the right ocular and eye keeping both eyes open. Adjust the correction (focusing) collar on

23                                                      December 2005

 

the left ocular by focusing the left ocular until it reads the same as the interpupillary distance. Bring an image located in the center of the field of view into as sharp a focus as possible.

  • Transfer the card to between the left eye and

Again keeping both eyes open, bring the same image into as sharp a focus for the right eye as possible by adjusting the ocular correction (focusing) collar at the top of the right ocular.

  • Ocular adjustment for microscopes without binocular capability: This

procedure assumes a single focusing ocular. The following procedure assumes that only the right ocular is capable of adjustment.

  • Place a card between the right ocular and eye keeping

both eyes open. Using the fine adjustment, focus the image for the left eye to its sharpest point.

  • Transfer the card to between the left eye and

Keeping both eyes open, bring the image for the right eye into sharp focus by adjusting the ocular collar at the top of the ocular without touching the coarse or fine adjustment.

  • Calibration of an ocular micrometer: This section assumes that a reticle has been

installed in one of the oculars by a microscopy specialist and that a stage micrometer is available for calibrating the ocular micrometer (reticle). Once installed, the ocular reticle should be left in place. The more an ocular is manipulated the greater the probability is for it to become contaminated with dust particles. This calibration should be done for each objective in use on the microscope. If there is a top lens on the microscope, the calibration procedure must be done for the respective objective at each top lens setting. The procedure must be followed when the microscope is first used and each time the objective is changed.

  • Place the stage micrometer on the microscope stage, turn on the

transmitted light, and focus the micrometer image using the coarse and fine adjustment knobs for the objective to be calibrated. Continue adjusting the focus on the stage micrometer so you can distinguish between the large (0.1 mm) and the small (0.01 mm) divisions.

  • Adjust the stage and ocular with the micrometer so the “0″ line on the

ocular micrometer is exactly superimposed on the “0″ line on the stage micrometer.

  • Without changing the stage adjustment, find a point as distant as possible from the two 0 lines where two other lines are exactly
  • Determine the number of ocular micrometer spaces as well as the number

of millimeters on the stage micrometer between the two points of superimposition. For example: Suppose 48 ocular micrometer spaces equal 0.6 mm.

  • Calculate the number of mm/ocular micrometer space. For example:

                       0.6 mm                                             0.0125 mm               

=

48 ocular micrometer spaces                     ocular micrometer space

December 2005                                        24

  • Because most measurements of microorganisms are given in µm rather

than mm, the value calculated above must be converted to µm by multiplying it by 1000 µm/mm. For example:

             0.0125 mm                ocular micrometer space

    1,000 µm                    12.5 µm             x                =

mm              ocular micrometer space

  • Follow the procedure below for each objective. Record the information as

shown in the example below and keep the information available at the microscope.

Item no. Objective power Description No. of ocular micrometer spaces No. of stage micrometer

1

mm

µm/ocular micrometer

2

space

1 10X 3

N.A. =

2 20X N.A.=
3 40X N.A.=
4 100X N.A.=

11000 µm/mm

2(Stage micrometer length in mm ◊ (1000 µm/mm)) ÷ no. ocular micrometer spaces

3N.A. refers to numerical aperature. The numerical aperature value is engraved on the barrel of the objective.

  • Köhler illumination: This section assumes that Köhler illumination will be established

for only the 100X oil DIC objective that will be used to identify internal morphological characteristics in Cryptosporidium oocysts and Giardia cysts. If more than one objective is to be used for DIC, then each time the objective is changed, Köhler illumination must be reestablished for the new objective lens. Previous sections have adjusted oculars and light sources. This section aligns and focuses the light going through the condenser underneath the stage at the specimen to be observed. If Köhler illumination is not properly established, then DIC will not work to its maximal potential. These steps need to become second nature and must be practiced regularly until they are a matter of reflex rather than a chore. The procedure must be followed each time an analyst uses the microscope and each time the objective is changed.

  • Place a prepared slide on the microscope stage, place oil on the slide,

move the 100X oil objective into place, turn on the transmitted light, and focus the specimen image using the coarse and fine adjustment knobs.

  • At this point both the radiant field diaphragm in the microscope base and

the aperture diaphragm in the condenser should be wide open. Now close down the radiant field diaphragm in the microscope base until the lighted field is reduced to a small opening.

  • Using the condenser centering screws on the front right and left of the

condenser, move the small lighted portion of the field to the center of the visual field.

  • Now look to see whether the leaves of the iris field diaphragm are sharply

defined (focused) or not. If they are not sharply defined, then they can be focused distinctly by changing the height of the condenser up and down with the condenser focusing knob while you are looking through the binoculars. Once you have accomplished the precise focusing of the

25                                                      December 2005

 

radiant field diaphragm leaves, open the radiant field diaphragm until the leaves just disappear from view.

  • The aperture diaphragm of the condenser should now be adjusted to make

it compatible with the total numerical aperture of the optical system. This is done by removing an ocular, looking into the tube at the rear focal plane of the objective, and stopping down the aperture diaphragm iris leaves until they are visible just inside the rear plane of the objective.

  • After completing the adjustment of the aperture diaphragm in the

condenser, return the ocular to its tube and proceed with the adjustments required to establish DIC.

  • Microscope cleaning procedure
    • Use canned air to remove dust from the lenses, filters, and microscope
    • Use a Kimwipe-dampened with a microscope cleaning solution (MCS) (consisting of 2

parts 90% isoproponal and 1 part acetone) to wipe down all surfaces of the microscope body. Dry off with a clean, dry Kimwipe.

  • Protocol for cleaning oculars and condenser
    • Use a new, clean Q-tip dampened with MCS to clean each lense. Start at

the center of the lens and spiral the Q-tip outward using little to no pressure. Rotate the Q-tip head while spiraling to ensure a clean surface is always contacting the lens.

  • Repeat the procedure using a new, dry Q-tip.
  • Repeat Sections 10.4.3.1 and 4.3.2.
  • Remove the ocular and repeat the cleaning procedure on the bottom lens of the
  • Protocol for cleaning objective lenses
    • Wipe 100X oil objective with lens paper to remove the bulk of the oil from the
    • Hold a new Q-tip dampened with MCS at a 45° angle on the objective

and twirl.

  • Repeat Sections 10.4.4.2 with a new, dry Q-tip.
  • Repeat Sections 10.4.4.2 and 4.4.3.
  • Clean all objectives whether they are used or
  • Protocol for cleaning light source lens and filters
    • Using a Kimwipe dampened with microscope cleaning solution, wipe off the surface of each lens and
    • Repeat the procedure using a dry
    • Repeat Sections 10.4.5.1 and 4.5.2.
  • Protocol for cleaning microscope stage
    • Using a Kimwipe dampened with microscope cleaning solution, wipe off

the stage and stage clip. Be sure to clean off any residual immersion oil or fingernail polish. Remove the stage clip if necessary to ensure that it is thoroughly cleaned.

  • Use 409 and a paper towel to clean the bench top surrounding the
  • Frequency

10.4.8.1         Perform Sections 10.4.2, 10.4.3, 10.4.4, 10.4.5 and 10.4.7 after each

December 2005                                        26

 

microscope session.

10.4.8.2         Perform complete cleaning each week.

  • Protozoa libraries: Each laboratory is encouraged to develop libraries of photographs and drawings for identification of
    • Take color photographs of Cryptosporidium oocysts and Giardia cysts by FA, 4′,6-

diamidino-2-phenylindole (DAPI), and DIC that the analysts (Section 22.2) determine are accurate (Section 15.2).

  • Similarly, take color photographs of interfering organisms and materials by FA, DAPI ,

and DIC that the analysts believe are not Cryptosporidium oocysts or Giardia cysts. Quantify the size, shape, microscope settings, and other characteristics that can be used to differentiate oocysts and cysts from interfering debris and that will result in accurate identification of positive or negative organisms.

  • Verification of analyst performance: Until standard reference materials, such as National Institute of Standards and Technology standard reference materials, are available that contain a reliable number of DAPI positive or negative oocysts and cysts, this method shall rely upon the ability of the analyst for identification and enumeration of oocysts and cysts. The goal of analyst verification is to encourage comparison and discussion among analysts to continually refine the consistency of characterizations between
    • At least monthly when microscopic examinations are being performed, the laboratory

shall prepare a slide containing 40 to 200 oocysts and 40 to 200 cysts. More than 50% of the oocysts and cysts must be DAPI positive and undamaged under DIC.

  • Each analyst shall determine the total number of oocysts and cysts detected by FITC on

the entire slide meeting the criteria in 10.6.1. For the same 10 oocysts and 10 cysts, each analyst shall determine the DAPI category (DAPI negative, DAPI positive internal intense blue and DAPI positive number of nuclei) and the DIC category (empty, containing amorphous structures, or containing identifiable internal structures) of each. The DAPI/DIC comparisons may be performed on the slide prepared in 10.6.1, OPR slide, MS slide, or a positive staining control slide.

  • Requirements for laboratories with multiple analysts
    • The total number of oocysts and cysts determined by each analyst

(Section 10.6.2.) must be within ±10% of each other. If the number is not within this range, the analysts must identify the source of any variability between analysts’ examination criteria, prepare a new slide, and repeat  the performance verification (Sections 10.6.1 to 10.6.2). It is recommended that the DAPI and DIC categorization of the same 10 oocysts and 10 cysts occur with all analysts at the same time, i.e. each analyst determines the categorizations independently, then the differences in the DAPI and DIC categorizations among analysts are discussed and resolved, and these resolutions documented. Alternatively, organism coordinates may be recorded for each analyst to locate and categorize the organisms at different times. Differences among analysts must be discussed and resolved.

  • Document the date, name(s) of analyst(s), number of total oocysts and

cysts, and DAPI and DIC categories determined by the analyst(s), whether the test was passed/failed and the results of attempts before the test was passed.

  • Only after an analyst has passed the criteria in Section 10.6.3, may

oocysts and cysts in QC samples and field samples be identified and enumerated.

27                                                      December 2005

 

  • Laboratories with only one analyst should maintain a protozoa library (Section 10.5) and

compare the results of the examinations performed in Sections 10.6.1 and 10.6.2 to photographs of oocysts and cysts and interfering organisms to verify that examination results are consistent with these references. These laboratories also should perform repetitive counts of a single verification slide for FITC. These laboratories should also coordinate with other laboratories to share slides and compare counts.

11.0            Oocyst and Cyst Suspension Enumeration and Sample Spiking

  • This method requires routine analysis of spiked QC samples to demonstrate acceptable initial and ongoing laboratory and method performance (initial precision and recovery samples [Section 9.4], matrix spike and matrix spike duplicate samples [Section 9.5], and ongoing precision and recovery samples [Section 9.7]). The organisms used for these samples must be enumerated to calculate recoveries (and precision) and monitor method performance. EPA recommends that flow cytometry be used for this enumeration, rather than manual techniques. Flow cytometer–sorted spikes generally are characterized by a relative standard deviation of #5%, versus greater variability for manual enumeration techniques (Reference 20.11). Guidance on preparing spiking suspensions using a flow cytometer is provided in Section 11.2. Manual enumeration procedures are provided in Section 11.3. The procedure for spiking bulk samples in the laboratory is provided in Section 11.4.
  • Flow cytometry enumeration guidelines. Although it is unlikely that many laboratories performing Method 1623 will have direct access to a flow cytometer for preparing spiking suspensions, flow-sorted suspensions are available from commercial vendors and other sources (Section 7.10.1). The information provided in Sections 11.2.1 through 11.2.4 is simply meant as a guideline for preparing spiking suspensions using a flow cytometer. Laboratories performing flow cytometry must develop and implement detailed standardized protocols for calibration and operation of the flow
    • Spiking suspensions should be prepared using unstained organisms that have not been formalin-fixed.
    • Spiking suspensions should be prepared using Cryptosporidium parvum oocysts <3

months old, and Giardia intestinalis cysts <2 weeks old.

  • Initial calibration. Immediately before sorting spiking suspensions, an initial calibration

of the flow cytometer should be performed by conducting 10 sequential sorts directly onto membranes or well slides. The oocyst and cyst levels used for the initial calibration should be the same as the levels used for the spiking suspensions. Each initial calibration sample should be stained and manually counted microscopically and the manual counts used to verify the accuracy of the system. The relative standard deviation (RSD) of the  10 counts should be # 2.5%. If the RSD is > 2.5%, the laboratory should perform the initial calibration again, until the RSD of the 10 counts is # 2.5%. In addition to counting the organisms, the laboratory also should evaluate the quality of the organisms using DAPI fluorescence and DIC to confirm that the organisms are in good condition.

  • Ongoing calibration. When sorting the spiking suspensions for use in QC samples, the

laboratory should perform ongoing calibration samples at a 10% frequency, at a minimum. The laboratory should sort the first run and every eleventh sample directly onto a membrane or well slide. Each ongoing calibration sample should be stained and manually counted microscopically and the manual counts used to verify the accuracy of the system. The mean of the ongoing calibration counts also should be used as the estimated spike dose, if the relative standard deviation (RSD) of the ongoing calibration counts is # 2.5%. If the RSD is > 2.5%, the laboratory should discard the batch.

  • Method blanks. Depending on the operation of the flow cytometer, method blanks should be prepared and examined at the same frequency as the ongoing calibration

December 2005                                        28

 

samples (Section 11.2.4).

  • Holding time criteria. Flow-cytometer-sorted spiking suspensions (Sections 7.10.1 and

11.2) used for spiked quality control (QC) samples (Section 9) must be used within the expiration date noted on the suspension. The holding time specified by the flow cytometry laboratory should be determined based on a holding time study.

  • Manual enumeration procedures. Two sets of manual enumerations are required per organism before purified Cryptosporidium oocyst and Giardia cyst stock suspensions (Section 7.10.2) received from suppliers can be used to spike samples in the laboratory. First, the stock suspension must be diluted and enumerated (Section 11.3.3) to yield a suspension at the appropriate oocyst or cyst concentration for spiking (spiking suspension). Then, 10 aliquots of spiking suspension must be enumerated to calculate a mean spike dose. Spiking suspensions can be enumerated using hemacytometer chamber counting (Section 11.3.4), well slide counting (Section 11.3.5), or membrane filter counting (Section 3.6).
    • Precision criteria. The relative standard deviation (RSD) of the calculated mean spike dose for manually enumerated spiking suspensions must be #16% for Cryptosporidium

and #19% for Giardia before proceeding (these criteria are based on the pooled RSDs  of

105 manual Cryptosporidium enumerations and 104 manual Giardia enumerations submitted by 20 different laboratories under the EPA Protozoa Performance Evaluation Program).

  • Holding time criteria. Manually enumerated spiking suspensions must be used within

24 hours of enumeration of the spiking suspension if the hemacytometer chamber technique is used (Section 11.3.4); or within 24 hours of application of the spiking suspension or membrane filter to the slides if the well slide or membrane filter enumeration technique is used (Sections 11.3.5 and 11.3.6).

  • Enumerating and diluting stock suspensions
    • Purified, concentrated stock suspensions (Sections 7.10.2.1 and 10.2.2)

must be diluted and enumerated before the diluted suspensions are used to spike samples in the laboratory. Stock suspensions should be diluted with reagent water/Tween® 20 , 0.01% (Section 7.10.2.3), to a concentration of 20 to 50 organisms per large hemacytometer square before proceeding to Section 11.3.3.2.

  • Apply a clean hemacytometer coverslip (Section 6.4.5) to the

hemacytometer and load the hemacytometer chamber with 10 µL of vortexed suspension per chamber. If this operation has been properly executed, the liquid should amply fill the entire chamber without bubbles or overflowing into the surrounding moats. Repeat this step with a clean, dry hemacytometer and coverslip if loading has been incorrectly performed. See Section 11.3.3.13, below, for the hemacytometer cleaning procedure.

  • Place the hemacytometer on the microscope stage and allow the oocysts

or cysts to settle for 2 minutes. Do not attempt to adjust the coverslip, apply clips, or in any way disturb the chamber after it has been filled.

  • Use 200X
  • Move the chamber so the ruled area is centered underneath the
  • Move the objective close to the coverslip while watching it from the side of the microscope, rather than through the
  • Focus up from the coverslip until the hemacytometer ruling
  • At each of the four corners of the chamber is a 1-square-mm area divided into 16 squares in which organisms are to be counted (Figure 1).

29                                                      December 2005

 

Beginning with the top row of four squares, count with a hand-tally counter in the directions indicated in Figure 2. Avoid counting organisms twice by counting only those touching the top and left boundary lines.

Count each square millimeter in this fashion.

  • Use the following formula to determine the number of organisms per µL of suspension:

number of

dilution

3                                       number of

    organisms counted            10

factor              1 mm

organisms

number of mm2

◊                 ◊                    ◊                       =

counted                  1 mm               1                   1 µL                    µL

  • Record the result on a hemacytometer data
  • A total of six different hemacytometer chambers must be loaded, counted, and averaged for each suspension to achieve optimal counting
  • Based on the hemacytometer counts, the stock suspension should be

diluted to a final concentration of between 8 to 12 organisms per µL;

                                                however, ranges as great as 5 to 15 organisms per µL can be used.        

NOTE:  If the diluted stock suspensions (the spiking suspensions) will be enumerated

using hemacytometer chamber counts (Section 11.3.4) or membrane filter counts (Section 11.3.6), then the stock suspensions should be diluted with 0.01% Tween® 20 . If the spiking suspensions will be enumerated using well slide counts (Section 11.3.5), then the stock suspensions should be diluted in reagent water.

To calculate the volume (in µL) of stock suspension required per µL of reagent water (or reagent water/Tween® 20 , 0.01%), use the following formula:

volume of stock suspension (µL) required =

             required number of organisms                     number of organisms/ µL of stock suspension

If the volume is less than 10 µL, an additional dilution of the stock suspension is recommended before proceeding.

To calculate the dilution factor needed to achieve the required number of organisms per 10 µL, use the following formula:

total volume (:L) =

                  number of organisms required x 10:L                      predicted number of organisms per 10:L (8 to 12)

To calculate the volume of reagent water (or reagent water/Tween® 20 , 0.01%) needed, use the following formula:

reagent water volume (:L) =     total volume (:L) –   stock suspension volume required (:L)

  • After each use, the hemacytometer and coverslip must be cleaned

immediately to prevent the organisms and debris from drying on it. Since this apparatus is precisely machined, abrasives cannot be used to clean it,

December 2005                                        30

 

as they will disturb the flooding and volume relationships.

  • Rinse the hemacytometer and cover glass first with tap water, then 70% ethanol, and finally with
  • Dry and polish the hemacytometer chamber and cover

glass with lens paper. Store it in a secure place.

  • Several factors are known to introduce errors into hemacytometer counts, including:

C          Inadequate mixing of suspension before flooding the chamber

C          Irregular filling of the chamber, trapped air bubbles, dust, or oil on the chamber or coverslip

C          Total number of organisms counted is too low to provide statistical confidence in the result

C          Error in recording tally

C          Calculation error; failure to consider dilution factor, or area counted

C          Inadequate cleaning and removal of organisms from the previous count

C          Allowing filled chamber to sit too long, so that the chamber suspension dries and concentrates.

  • Enumerating spiking suspensions using a hemacytometer chamber

NOTE: Spiking suspensions enumerated using a hemacytometer chamber must be used within 24 hours of enumeration.

  • Vortex the tube containing the spiking suspension (diluted stock

suspension; Section 11.3.3) for a minimum of 2 minutes. Gently invert the tube three times.

  • To an appropriate-size beaker containing a stir bar, add enough spiking

suspension to perform all spike testing and the enumeration as described. The liquid volume and beaker relationship should be such that a spinning stir bar does not splash the sides of the beaker, the stir bar has unimpeded rotation, and there is enough room to draw sample from the beaker with a 10-µL micropipette without touching the stir bar. Cover the beaker with a watch glass or petri dish to prevent evaporation between sample withdrawals.

  • Allow the beaker contents to stir for a minimum of 30 minutes before beginning
  • While the stir bar is still spinning, remove a 10-µL aliquot and carefully

load one side of the hemacytometer. Count all organisms on the platform, at 200X magnification using phase-contrast or darkfield microscopy. The count must include the entire area under the hemacytometer, not just the four outer 1-mm2 squares. Repeat this procedure nine times. This step allows confirmation of the number of organisms per 10 µL (Section 11.3.3.12). Based on the 10 counts, calculate the mean, standard deviation, and RSD of the counts. Record the counts and the calculations on a spiking suspension enumeration form. The relative standard deviation (RSD) of the calculated mean spike dose must be #16% for Cryptosporidium and #19% for Giardia before proceeding. If the RSD is unacceptable, or the mean number is outside the expected range, add

31                                                      December 2005

 

additional oocysts from stock suspension or dilute the contents of the beaker appropriately with reagent water. Repeat the process to confirm counts. Refer to Section 11.3.3.14 for factors that may introduce errors.

  • Enumerating spiking suspensions using well slides

NOTE: Spiking suspensions enumerated using well slides must be used within 24 hours of application of the spiking suspension to the slides.

  • Prepare well slides for sample screening and label the
  • Vortex the tube containing the spiking suspension (diluted stock

suspension; Section 11.3.3) for a minimum of 2 minutes. Gently invert the tube three times.

  • Remove a 10-µL aliquot from the spiking suspension and apply it to the center of a
  • Before removing subsequent aliquots, cap the tube and gently invert it

three times to ensure that the oocysts or cysts are in suspension.

  • Ten wells must be prepared and counted, and the counts averaged, to

sufficiently enumerate the spike dose. Air-dry the well slides. Because temperature and humidity varies from laboratory to laboratory, no minimum time is specified. However, the laboratory must take care to ensure that the sample has dried completely before staining to prevent losses during the rinse steps. A slide warmer set at 35°C to 42°C also can be used.

  • Positive and negative controls must be
    • For the positive control, pipette 10 µL of positive antigen

or 200 to 400 intact oocysts or cysts to the center of a well and distribute evenly over the well area.

  • For the negative control, pipette 50 µL of PBS onto the

center of a well and spread it over the well area with a pipette tip.

  • Air-dry the control
  • Follow the manufacturer’s instructions (Section 7.6) in applying the stain to the
  • Place the slides in a humid chamber in the dark and incubate according to

manufacturer’s directions. The humid chamber consists of a tightly sealed plastic container containing damp paper towels on top of which the slides are placed.

  • Apply one drop of wash buffer (prepared according to the manufacturer’s

instructions [Section 7.6]) to each well. Tilt each slide on a clean paper towel, long edge down. Gently aspirate the excess detection reagent from below the well using a clean Pasteur pipette or absorb with a paper towel

                                                or other absorbent material. Avoid disturbing the sample.                     

NOTE: If using the MeriFluor® Cryptosporidium/Giardia stain (Section 7.6.1), do not allow slides to dry completely.

 

  • Add mounting medium (Section 7.8) to each

December 2005                                        32

 

  • Apply a cover slip. Use a tissue to remove excess mounting fluid from the

edges of the coverslip. Seal the edges of the coverslip onto the slide using clear nail polish.

  • Record the date and time that staining was completed. If slides will not be

read immediately, store in a humid chamber in the dark between 1°C and 10°C until ready for examination.

  • After examination of the 10 wells, calculate the mean, standard deviation,

and RSD of the 10 replicates. Record the counts and the calculations on a spiking suspension enumeration form. The relative standard deviation (RSD) of the calculated mean spike dose must be #16% for Cryptosporidium and #19% for Giardia before proceeding. If the RSD is unacceptable, or the mean number is outside the expected range, add additional oocysts from stock suspension or dilute the contents of the beaker appropriately with reagent water. Repeat the process to confirm counts.

  • Enumeration of spiking suspensions using membrane filters

NOTE: Spiking suspensions enumerated using membrane filters must be used within 24 hours of application of the filters to the slides.

  • Precoat the glass funnels with Sigmacote® by placing the funnel in a

large petri dish and applying 5-mL of Sigmacoat® to the funnel opening using a pipette and allowing it to run down the inside of the funnel.

Repeat for all funnels to be used. The pooled Sigmacoat® may be returned to the bottle for re-use. Place the funnels at 35°C or 41°C for approximately 5 minutes to dry.

  • Place foil around the bottoms of the 100 ◊ 15 mm petri
  • Filter-sterilize (Section 6.19) approximately 10 mL of PBS (Section

7.4.2.1). Dilute detection reagent (Section 7.6) as per manufacturer’s instructions using sterile PBS. Multiply the anticipated number of filters to be stained by 100 mL to calculate total volume of stain required.

Divide the total volume required by 5 to obtain the microliters of antibody necessary. Subtract the volume of antibody from the total stain volume to obtain the required microliters of sterile PBS to add to the antibody.

  • Label the tops of foil-covered, 60 ◊ 15 mm petri dishes for 10 spiking

suspensions plus positive and negative staining controls and multiple filter blanks controls (one negative control, plus a blank after every five sample filters to control for carry-over). Create a humid chamber by laying damp paper towels on the bottom of a stain tray (the inverted foil- lined petri dishes will protect filters from light and prevent evaporation during incubation).

  • Place a decontaminated and cleaned filter holder base (Section 6.4.8.1) into each of the three ports of the vacuum manifold (Section 4.8.2).
  • Pour approximately 10 mL of 0.01% Tween® 20 into a 60 ◊ 15 mm petri

dish.

  • Using forceps, moisten a 1.2-µm cellulose-acetate support membrane

(Section 6.4.8.3) in the 0.01% Tween® 20 and place it on the fritted glass support of one of the filter bases. Moisten a polycarbonate filter (Section 6.4.8.4) the same way and position it on top of the cellulose-

33                                                      December 2005

 

acetate support membrane. Carefully clamp the glass funnel to the loaded filter support. Repeat for the other two filters.

  • Add 5 mL of 0.01% Tween® 20 to each of the three filtration units and allow to
  • Vortex the tube containing the spiking suspension (diluted stock

suspension; Section 11.3.3) for a minimum of 2 minutes. Gently invert the tube three times.

  • Using a micropipettor, sequentially remove two, 10-µL aliquots from the

spiking suspension and pipet into the 5 mL of 0.01% Tween® 20 standing in the unit. Rinse the pipet tip twice after each addition. Apply 10 µL of 0.01% Tween® 20 to the third unit to serve as the negative control. Apply vacuum at 2″ Hg and allow liquid to drain to miniscus, then close off vacuum. Pipet 10 mL of reagent water into each funnel and drain to miniscus, closing off the vacuum. Repeat the rinse and drain all fluid, close off the vacuum.

  • Pipet 100 mL of diluted antibody to the center of the bottom of a 60 ◊ 15 mm petri dish for each
  • Unclamp the top funnel and transfer each cellulose acetate support

membrane/ polycarbonate filter combination onto the drop of stain using forceps (apply each membrane/filter combination to a different petri dish containing stain). Roll the filter into the drop to exclude air. Place the small petri dish containing the filter onto the damp towel and cover with the corresponding labeled foil-covered top. Incubate for approximately 45 minutes at room temperature.

  • Reclamp the top funnels, apply vacuum and rinse each three times, each time with 20 mL of reagent
  • Repeat Sections 11.3.6.4 through 11.3.6.10 for the next three samples (if

that the diluted spiking suspension has sat less than 15 minutes, reduce  the suspension vortex time to 60 seconds). Ten, 10-µL spiking suspension aliquots must be prepared and counted, and the counts averaged, to sufficiently enumerate the spike dose. Include a filter blank sample at a frequency of every five samples; rotate the position of filter blank to eventually include all three filter placements.

  • Repeat Sections 11.3.6.4 through 11.3.6.10 until the 10-µL spiking suspensions have been filtered. The last batch should include a 10-µL

0.01 Tween® 20  blank control and 20 µL of positive control antigen as a

positive staining control.

  • Label slides. After incubation is complete, for each sample, transfer the

cellulose acetate filter support and polycarbonate filter from drop of stain and place on fritted glass support. Cycle vacuum on and off briefly to remove excess fluid. Peel the top polycarbonate filter off the supporting filter and place on labeled slide. Discard cellulose acetate filter support. Mount and apply coverslips to the filters immediately to avoid drying.

  • To each slide, add 20 µL of mounting medium (Section 8).
  • Apply a coverslip. Seal the edges of the coverslip onto the slide using

clear nail polish. (Sealing may be delayed until cover slips are applied to all slides.)

December 2005                                        34

 

  • Record the date and time that staining was completed. If slides will not be

read immediately, store sealed slides in a closed container in the dark between 1°C and 10°C until ready for examination.

  • After examination of the 10 slides, calculate the mean, standard

deviation, and RSD of the 10 replicates. Record the counts and the calculations on a spiking suspension enumeration form. The relative standard deviation (RSD) of the calculated mean spike dose must be

#16% for Cryptosporidium and #19% for Giardia before proceeding. If the RSD is unacceptable, or the mean number is outside the expected range, add additional oocysts from stock suspension or dilute the contents of the beaker appropriately with reagent water. Repeat the process to confirm counts.

  • If oocysts or cysts are detected on the filter blanks, modify the rinse procedure to ensure that no carryover occurs and repeat
  • Procedure for spiking samples in the laboratory with enumerated spiking
    • Arrange a disposable cubitainer or bottom-dispensing container to feed the filter or insert

the influent end of the tube connected to the filter through the top of a carboy to allow siphoning of the sample.

  • For initial precision and recovery (Section 9.4) and ongoing precision and recovery

(Section 9.7) samples, fill the container with 10 L of reagent water or a volume of reagent water equal to the volume of the field samples analyzed in the analytical batch. For matrix spike samples (Section 9.5), fill the container with the field sample to be spiked. Continuously mix the sample (using a stir bar and stir plate for smaller-volume samples and alternate means for larger-volume samples).

  • Follow the procedures in Section 11.4.3.1 or manufacturer’s instructions for flow

cytometer–enumerated suspensions and the procedures in Section 11.4.3.2 for manually enumerated suspensions.

  • For flow cytometer–enumerated suspensions (where the entire volume of a spiking suspension tube will be used):
    • Add 400 µL of Antifoam A to 100 mL of reagent water,

and mix well to emulsify.

  • Add 500 µL of the diluted antifoam to the tube

containing the spiking suspension and vortex for 30 seconds.

  • Pour the suspension into the sample
  • Add 20 mL of reagent water to the empty tube, cap,

vortex 10 seconds to rinse, and add the rinsate to the carboy.

  • Repeat this rinse using another 20 mL of reagent
  • Record the estimated number of organisms spiked, the

date and time the sample was spiked, and the sample volume spiked on a bench sheet. Proceed to Section 11.4.4.

  • For manually enumerated spiking suspensions:
    • Vortex the spiking suspension(s) (Section 11.2 or Section 11.3) for a minimum of 30
    • Rinse a pipette tip with 0.01% Tween® 20 once, then

repeatedly pipette the well-mixed spiking suspension a

35                                                      December 2005

 

minimum of five times before withdrawing an aliquot to spike the sample.

  • Add the spiking suspension(s) to the carboy, delivering the aliquot below the surface of the
  • Record the estimated number of organisms spiked, the

date and time the sample was spiked, and the sample volume spiked on a bench sheet. Proceed to Section 11.4.4

  • Allow the spiked sample to mix for approximately 1 minute in the
  • Turn on the pump and allow the flow rate to stabilize. Set flow at the rate designated for

the filter being used. As the carboy is depleted, check the flow rate and adjust if necessary.

  • When the water level approaches the discharge port of the carboy, tilt the container so

that it is completely emptied. At that time, turn off the pump and add 1-L PBST or reagent water to the 10-L carboy to rinse (5 L PBST or reagent water rinse to 50-L carboy). Swirl the contents to rinse down the sides. Additional rinses may be performed.

  • Turn on the pump. Allow all of the water to flow through the filter and turn off the pump.
  • Proceed to filter

12.0            Sample Filtration and Elution

  • A water sample is filtered according to the procedures in Section 12.2, 12.3, or 12.4. Alternate procedures may be used if the laboratory first demonstrates that the alternate procedure provides equivalent or superior performance per Section 1.2.

NOTE: Sample elution must be initiated within 96 hours of sample collection (if shipped to the laboratory as a bulk sample) or filtration (if filtered in the field).

  • Capsule filtration (adapted from Reference 20.12). This procedure was validated using 10-L sample volumes (for the original Envirochek ™ filter) and 50-L sample volumes (for the Envirochek™ HV filter). Alternate sample volumes may be used, provided the laboratory demonstrates acceptable performance on initial and ongoing spiked reagent water and source water samples (Section 1.2).
    • Flow rate adjustment
      • Connect the sampling system, minus the capsule, to a carboy filled with reagent water (Figure 3).
      • Turn on the pump and adjust the flow rate to 2.0 L/min.
      • Allow 2 to 10 L of reagent water to flush the Adjust the pump

speed as required during this period. Turn off the pump when the flow rate has been adjusted.

  • Install the capsule filter in the line, securing the inlet and outlet ends with the appropriate clamps/fittings.
  • Record the sample number, sample turbidity (if not provided with the field sample),

sample type, and sample filtration start date and time on a bench sheet.

  • Filtration
    • Mix the sample well by shaking, add stir bar and place on stir plate. Turn

on stir plate to lowest setting needed to keep sample thoroughly mixed. Connect the sampling system to the field carboy of sample water, or

December 2005                                        36

transfer the sample water to the laboratory carboy used in Section

12.2.1.1. If the sample will be filtered from a field carboy, a spigot (Section 6.2.1) can be used with the carboy to facilitate sample filtration.

NOTE: If the bulk field sample is transferred to a laboratory carboy, the laboratory carboy must be cleaned and disinfected before it is used with another field sample.

 

12.2.4.2 Place the drain end of the sampling system tubing into an empty
graduated container with a capacity of 10 to 15 L, calibrated at 9.0, 9.5,

10.0, 10.5, and 11.0 L (Section 6.18). This container will be used to determine the sample volume filtered. Alternately, connect a flow meter (Section 6.3.4) downstream of the filter, and record the initial meter reading.

12.2.4.3 Allow the carboy discharge tube and capsule to fill with sample water by
gravity. Vent residual air using the bleed valve/vent port, gently shaking

or tapping the capsule, if necessary. Turn on the pump to start water flowing through the filter. Verify that the flow rate is 2 L/min.

12.2.4.4 After all of the sample has passed through the filter, turn off the pump.
Allow the pressure to decrease until flow stops. (If the sample was

filtered in the field, and excess sample remains in the filter capsule upon receipt in the laboratory, pull the remaining sample volume through the filter before eluting the filter [Section 12.2.6].)

12.2.4.5 Turn off stir plate; add 1 L PBST or reagent water rinse (to 10-L carboy)
or 5 L PBST or reagent water rinse (to 50-L carboy).  Swirl or shake the

carboy to rinse down the side walls.

12.2.4.6 Reconnect to pump, turn on pump and allow pump to pull all water
through filter; turn off pump.
12.2.5 Disassembly
12.2.5.1 Disconnect the inlet end of the capsule filter assembly while maintaining
the level of the inlet fitting above the level of the outlet fitting to prevent

backwashing and the loss of oocysts and cysts from the filter. Restart the pump and allow as much water to drain as possible. Turn off the pump.

12.2.5.2 Based on the water level in the graduated container and Ω-L hash marks
or meter reading, record the volume filtered on the bench sheet to the

nearest quarter liter. Discard the contents of the graduated container.

12.2.5.3 Loosen the outlet fitting, then cap the inlet and outlet fittings.
12.2.6 Elution

NOTE:  The laboratory must complete the elution, concentration, and  purification

(Sections 12.2.6 through 13.3.3.11) in one work day. It is critical that these steps be completed in one work day to minimize the time that any target organisms present in the sample sit in eluate or concentrated matrix. This process ends with the application of the purified sample on the slide for drying.

12.2.6.1         Setup

12.2.6.1.1        Assemble the laboratory shaker with the clamps aligned

vertically so that the filters will be aligned horizontally. Extend the clamp arms to their maximum distance from the horizontal shaker rods to maximize the shaking action.

37                                                      December 2005

 

12.2.6.1.2 Prepare sufficient quantity of elution buffer to elute all
samples that are associated with the OPR/MB which used

that batch of elution buffer. Elution may require up to 275 mL of buffer per sample.

12.2.6.1.3 Designate at least one 250-mL conical centrifuge tube for
each sample and label with the sample number.
12.2.6.2 Elution
12.2.6.2.1 Record the elution date and time on the bench sheet.
Using a ring stand or other means, clamp each capsule in

a vertical position with the inlet end up.

12.2.6.2.2 Remove the inlet cap, pour elution buffer through the
inlet fitting, and allow the liquid level to stabilize.

Sufficient elution buffer must be added to cover the pleated white membrane with buffer solution or elution buffer may be measured to ensure the use of one 250-mL centrifuge tube. Replace the inlet cap.

12.2.6.2.3 Securely clamp the capsule in one of the clamps on the
laboratory shaker with the bleed valve positioned at the

top on a vertical axis (in the 12 o’clock position). Turn on the shaker and set the speed to maximum (approximately 900 rpm or per manufacturer’s instructions). Agitate the capsule for approximately 5 minutes. Time the agitation using a lab timer, rather than the timer on the shaker to ensure accurate time measurement.

12.2.6.2.4 Remove the filter from the shaker, remove the inlet cap,
and pour the contents of the capsule into the 250-mL

conical centrifuge tube.

12.2.6.2.5 Clamp the capsule vertically with the inlet end up and
add sufficient volume of elution buffer through the inlet

fitting to cover the pleated membrane. Replace the inlet cap.

12.2.6.2.6 Return the capsule to the shaker with the bleed valve
positioned at the 4 o’clock position. Turn on the shaker

and agitate the capsule for approximately 5 minutes.

12.2.6.2.7 Remove the filter from the shaker, but leave the elution
buffer in the capsule. Re-clamp the capsule to the shaker

at the 8 o’clock position. Turn on the shaker and agitate the capsule for a final 5 minutes.

12.2.6.2.8 Remove the filter from the shaker and pour the contents
into the 250-mL centrifuge tube. Rinse down the inside

of the capsule filter walls with reagent water or elution buffer using a squirt bottle inserted in the inlet end of the capsule. Invert the capsule filter over the centrifuge tube and ensure that as much of the eluate as possible has been transferred.

12.2.7   Proceed to Section 13.0 for concentration and separation (purification).

  • Sample filtration using the Filta-Max® foam filter. This procedure was validated using 50-L sample volumes. Alternate sample volumes may be used, provided the laboratory demonstrates

December 2005                                        38

acceptable performance on initial and ongoing spiked reagent water and source water samples (Section 9.1.2).

NOTE:   The filtration procedures specified in Sections 12.3.1.2 – 12.3.1.6.3 are specific

to laboratory filtration of a bulk sample. These procedures may require modification if samples will be filtered in the field.

  • Filtration
    • Flow rate adjustment
      • Connect the sampling system, minus the filter housing, to a carboy filled with reagent
      • Place the peristaltic pump upstream of the filter
      • Turn on the pump and adjust the flow rate to 1 to 4 L per minute.

NOTE:  A head pressure of 0.5 bar (7.5 psi) is required to create flow through the  filter,

and the recommended pressure of 5 bar (75 psi) should produce the flow rate of 3 to 4 L per minute. The maximum operating pressure of 8 bar (120 psi) should not be exceeded.

  • Allow 2 to 10 L of reagent water to flush the

Adjust the pump speed as necessary during this period. Turn off the pump when the flow rate has been adjusted.

  • Place filter module into the filter housing bolt head down and secure lid,

hand tighten housings, apply gentle pressure to create the seal between the module and the ‘O’ rings in the base and the lid of the housing.

Excessive tightening is not necessary, and may shorten the life of the ‘O’ rings. Tools may be used to tighten housing to the alignment marks (refer to manufacturer’s instructions). ‘O’ rings should be lightly greased before use (refer to manufacturer’s instructions).

  • Install the filter housing in the line, securing the inlet and outlet ends with

the appropriate clamps/fittings. Verify that the filter housing is installed so that the end closest to the screw top cap is the inlet and the opposite end is the outlet.

  • Record the sample number, sample turbidity (if not provided with the

field sample), and the name of the analyst filtering the sample on a bench sheet.

  • Filtration
    • Connect the sampling system to the field carboy of

sample water, or transfer the sample water to the laboratory carboy used in Section 12.3.1.1.1. If the sample will be filtered from a field carboy, a spigot can be used with the carboy to facilitate sample filtration.

NOTE: If the bulk field sample is transferred to a laboratory carboy, the laboratory carboy must be cleaned and disinfected before it is used with another field sample.

  • Place the drain end of the sampling system tubing into an

empty graduated container with a capacity greater than or equal to the volume to be filtered. This container will be used to determine the sample volume filtered.

Alternately, connect a flow meter downstream of the filter, and record the initial meter reading.

39                                                      December 2005

 

  • Allow the carboy discharge tube and filter housing to fill

with sample water. Turn on the pump to start water flowing through the filter. Verify that the flow rate is between 1 and 4 L per min.

 

 

  • Disassembly

After all of the sample has passed through the filter, turn

off the pump. Allow the pressure to decrease until flow stops.

  • Disconnect the inlet end of the filter housing assembly

while maintaining the level of the inlet fitting above the level of the outlet fitting to prevent backwashing and the loss of oocysts and cysts from the filter. Restart the pump and allow as much water to drain as possible. Turn off the pump.

  • Based on the water level in the graduated container or the

meter reading, record the volume filtered on a bench sheet to the nearest quarter liter.

  • Loosen the outlet fitting, the filter housing should be sealed with rubber

NOTE: Filters should be prevented from drying out, as this can impair their ability to expand when decompressed.

  • Elution
    • The filter is eluted to wash the oocysts from the filter. This can be

accomplished using the Filta-Max® wash station, which moves a plunger up and down a tube containing the filter and eluting solution (Section 12.3.2.2), or a stomacher, which uses paddles to agitate the stomacher bag containing the foam filter in the eluting solution (Section 12.3.2.3). If the Filta-Max® automatic wash station is used please see the manufacturer’s operator’s guide for instructions on its use. If Filta-Max® Quick Connect kit is used please follow manufacturer’s instructions.

  • Filta-Max® wash station elution procedure
    • First wash
      • Detach the removable plunger head using the tool provided, and remove the splash
      • Place the filter membrane flat in the concentrator base with the rough side up. Locate the concentrator base in the jaws of the wash station and screw on the concentrator tube (the longer of the two tubes), creating a tight seal at the membrane. Take the assembled concentrator out of the jaws and place on the
      • Replace the splash guard and temporarily secure it at least 15 cm above the end of the Secure the plunger head with the tool provided ensuring that the lever is fully locked down.
      • Remove the filter module from the filter housing or transportation container. Pour excess liquid into the assembled concentrator, then rinse the housing or

December 2005                                        40

container with PBST and add the rinse to the concentrator tube. Screw the filter module onto the base of the plunger. Locate the elution tube base in the jaws of the wash station and screw the elution tube (the shorter of the two tubes) firmly in place.

  • Pull the plunger down until the filter module sits at the bottom of the elution tube; the locking pin (at the top left of the wash station) should “click” to lock the plunger in
  • Remove the filter module bolt by turning the adapted allen key (provided) in a clockwise direction (as seen from above). Attach the steel tube to the elution tube base.
  • Add 600 mL of PBST to the assembled concentrator. If more than 50 mL of liquid has been recovered from the shipped filter module, reduce the volume of PBST accordingly. Screw the concentrator tube onto the base beneath the elution tube. Release the locking pin.

NOTE: Gentle pressure on the lever, coupled with a pulling action on the locking pin should enable the pin to be easily released.

  • Wash the foam disks by moving the plunger up and down 20 Gentle movements of the plunger are recommended to avoid generating excess foam.

NOTE: The plunger has an upper movement limit during the wash process to prevent it popping out of the top of the chamber.

  • Detach the concentrator and hold it such that the stainless steel tube is just above the level of the liquid. Purge the remaining liquid from the elution tube by moving the plunger up and down 5 times, then lock the plunger in place. To prevent drips, place the plug provided in the end of the steel
  • Prior to the second wash the eluate from the first wash can be concentrated using the Filta-Max® apparatus according to Section 12.3.3.2.1 or the eluate can be decanted into a 2-L pooling beaker and set
  • Second wash
    • Add an additional 600 mL of PBST to the concentrator module, remove the plug from the end of the steel tube and screw the concentrator tube back onto the elution module base. Release the locking pin.
    • Wash the foam disks by moving the plunger up and down 10 Gentle movements of the plunger are recommended to avoid generating excess foam.

41                                                      December 2005

 

  • The eluate can be concentrated using the Filta-Max® apparatus according to Section 12.3.3.2.2 or the eluate can be decanted into the 2-L pooling beaker containing the eluate from the first wash and concentrated using centrifugation, as described in Section 3.3.3.
  • Stomacher elution procedure
    • First wash
      • Place the filter module in the stomacher bag then use the allen key to remove the bolt from the filter module, allowing the rings to expand. Remove the end caps from the stomacher bag and rinse with PBST into the stomacher
      • Add 600 mL of PBST to stomacher bag containing the filter pads. Place bag in stomacher and wash for 5 minutes on a normal
      • Remove the bag from the stomacher and decant the eluate into a 2-L pooling
    • Second wash
      • Add a second 600-mL aliquot of PBST to the stomacher bag. Place bag in stomacher and wash for 5 minutes on a normal setting. Remove the bag from the stomacher and decant the eluate from the stomacher bag into the 2-L pooling beaker. Wring the stomacher bag by hand to remove eluate from the foam filter and add to the pooling beaker. Remove the foam filter from the bag and using a squirt bottle, rinse the stomacher bag with reagent water and add the rinse to the pooling
      • Proceed to concentration (Section 3.3).
    • Concentration
      • The eluate can be concentrated using the Filta-Max® concentrator

apparatus, which pulls most of the eluate through a membrane filter leaving the oocysts concentrated in a small volume of the remaining eluting solution (Section 12.3..2), or by directly centrifuging all of the eluting solution used to wash the filter (Section 12.3.2.3).

  • The Filta-Max® concentrator procedure
    • Concentration of first wash
      • If the stomacher was used to elute the sample (Section 12.3.2.3), transfer 600 mL of eluate from the pooling beaker to the concentrator tube. Otherwise proceed to Step (b).
      • Stand the concentrator tube on a magnetic stirring plate and attach the lid (with magnetic stirrer bar). Connect the waste bottle trap and hand or electric vacuum pump to the valve on the concentrator base. Begin stirring and open the tap. Increase the vacuum using the hand

December 2005                                        42

NOTE:  The force of the vacuum should not exceed 30 cmHg.

  • Allow the liquid to drain until it is approximately level with the middle of the stirrer bar then close the valve. Remove the magnetic stirrer, and rinse it with PBST or distilled water to recover all oocysts. Decant the concentrate into a 50-mL tube, then rinse the sides of the concentration tube and add the rinsate to the 50-mL tube.
  • Concentration of second wash
    • If the stomacher was used to elute the sample (Section 12.3.2.3), transfer the remaining 600 mL of eluate from the pooling beaker to the concentrator tube. Otherwise proceed to Step (b).
    • Add the concentrate, in the 50-mL tube, retained from the first concentration (Section 12.3.3.2.1 (c)) to the 600 mL of eluate from the second wash, then repeat concentration steps from Sections 3.3.2.1
      • and 12.3.3.2.1 (c). The final sample can be poured into the same 50-mL tube used to retain the first concentrate. Rinse the sides of the concentrator tube with PBST and add the rinse to the 50-mL
      • Remove the magnetic stirrer. Insert the empty concentrator module into the jaws of the wash station and twist off the concentrator
      • Transfer the membrane from the concentrator base to the bag provided using membrane
    • Membrane elution. The membrane can be washed manually or using a stomacher:
  • Manual wash. Add 5 mL of PBST to the bag containing the membrane. Rub the surface of the membrane through the bag until the membrane appears clean. Using a pipette, transfer the eluate to a 50-mL tube. Repeat the membrane wash with another 5 mL of PBST and transfer the eluate to the 50-mL tube. (Optional: Perform a third wash using another 5 mL of PBST, by hand-kneading an additional minute or placing the bag on a flat-headed vortexer and vortexing for one Transfer the eluate to the

                                                                              50-mL tube.)                                                                 NOTE:  Mark the bag with an “X” to note which side of the membrane has the oocysts to encourage the hand-kneading to focus on the appropriate side of the membrane.

 

  • Stomacher wash. Add 5 mL of PBST to the bag containing the membrane. Place the bag containing the membrane into a small stomacher and stomach for 3 minutes. Using a pipette transfer the eluate to a 50-mL tube. Repeat the wash two times using the stomacher and 5-mL aliquots of (Optional:

43                                                      December 2005

 

Perform a fourth wash using another 5 mL of PBST, by hand-kneading an additional minute or placing the bag on a flat-headed vortexer and vortexing for one minute. Transfer the eluate to the 50-mL tube.)

  • If the membrane filter clogs before concentration is

complete, there are two possible options for completion of concentration. One option is replacing the membrane as often as necessary. Filter membranes may be placed smooth side up during the second concentration step.

Another option is concentrating the remaining eluate using centrifugation. Both options are provided below.

  • Using multiple membranes. Disassemble the concentrator tube and pour any remaining eluate back into the pooling beaker. Remove the membrane using membrane forceps, placing it in the bag provided. Place a new membrane in the concentrator tube smooth side up, reassemble, return the eluate to the concentrator tube, rinse the pooling beaker and add rinse to the eluate, and continue the concentration. Replace the membrane as often as
  • Centrifuging remaining volume. Decant the remaining eluate into a 2-L pooling beaker. Rinse the sides of the concentrator tube and add to the pooling beaker. Remove the filter membrane and place it in the bag provided. Wash the membrane as described in Section 12.3.3.2.3, then concentrate the sample as described in Section 3.3.3.1.
    • If the Filta-Max® concentrator is not used for sample concentration, or if

the membrane filter clogs before sample concentration is complete, then the procedures described in Section 12.3.3.3.1 should be used to concentrate the sample. If less than 50 mL of concentrate has been generated, the sample can be further concentrated, as described in Section 12.3.3.3.2, to reduce the volume of sample to be processed through IMS.

NOTE:  The volume must not be reduced to less than 5 mL above the packed pellet.  The

maximum amount of pellet that should be processed through IMS is 0.5 mL. If the packed pellet is greater than 0.5 mL then the pellet may be subsampled as described in Section 13.2.4.

  • Centrifugation of greater than 50 mL of eluate
  • Decant the eluate from the 2-L pooling beaker into 250-mL conical centrifuge tubes. Make sure that the centrifuge tubes are
  • Centrifuge the 250-mL centrifuge tubes containing the eluate at 1500 ◊ G for 15 minutes. Allow the centrifuge to coast to a
  • Using a Pasteur pipette, carefully aspirate off the supernatant to 5 mL above the pellet. If the sample is reagent water (e.g. initial or ongoing precision and recovery sample) extra care must be taken to avoid aspirating oocysts and cysts during this

December 2005                                        44

  • Vortex each 250-mL tube vigorously until pellet is completely resuspended. Swirl the centrifuge tube gently to reduce any foaming after vortexing. Combine the contents of each 250-mL centrifuge tube into a 50-mL centrifuge tube. Rinse each of the 250-mL centrifuge tubes with PBST and add the rinse to the 50-mL
  • Proceed to Section 3.3.3.2.
  • Centrifugation of less than 50 mL of eluate
  • Maintenance and cleaning
  • Centrifuge the 50-mL centrifuge tube containing the combined concentrate at 1500 x G for 15 minutes. Allow the centrifuge to coast to a stop. Record the initial pellet volume (volume of solids) and the date and time that concentration was completed on a bench
  • Proceed to Section 13.0 for concentration and separation (purification).
  • Maintenance of O-rings
    • Check all rubber O-rings for wear or deterioration prior to each use and replace as
    • Lubricate the plunger head O-ring inside and out with

silicon before each use.

  • Lubricate all other O-rings (concentrator tube set, filter housing) regularly in order to preserve their
  • Cleaning
    • All components of the Filta-Max® system can be cleaned

using warm water and laboratory detergent. After washing, rinse all components with oocyst and cyst free reagent water and dry them. All O-rings should be re- lubricated. Alternatively a mild (40°C) dishwasher cycle without bleach or rinse aid can be used.

  • To wash the detachable plunger head slide the locking

pin out and wash the plunger head and locking pin in warm water and laboratory detergent. Rinse the plunger head and locking pin with oocyst and cyst free reagent water and dry. Lightly lubricate the locking pin and re- assemble the plunger head.

  • Sample collection (filtration and concentration) using portable continuous-flow centrifugation. Please follow manufacturer’s instructions. This procedure was validated for the detection of Cryptosporidium using 50-L sample volumes. Alternate sample volumes may be used, provided the laboratory demonstrates acceptable performance on initial and ongoing spiked reagent water and source water samples (Section 9.1.2). Laboratories are permitted to demonstrate acceptable performance for Giardia in their individual

45                                                      December 2005

 

13.0            Sample Concentration and Separation (Purification)

  • During concentration and separation, the filter eluate is concentrated through centrifugation, and the oocysts and cysts in the sample are separated from other particulates through immunomagnetic separation (IMS). Alternate procedures and products may be used if the laboratory first demonstrates equivalent or superior performance as per Section 1.2.
  • Adjustment of pellet volume
    • Centrifuge the 250-mL centrifuge tube containing the capsule filter eluate at 1500 ◊ G

for 15 minutes. Allow the centrifuge to coast to a stop—do not use the brake. Record the pellet volume (volume of solids) on the bench sheet.

NOTE: Recoveries may be improved if centrifugation force is increased to 2000 ◊ G.

However, do not use this higher force if the sample contains sand or other gritty material that may degrade the condition of any oocysts and/or cysts in the sample.

  • Using a Pasteur pipette, carefully aspirate the supernatant to 5 mL above the pellet. Extra

care must be taken to avoid aspirating oocysts and cysts during this step, particularly if the sample is reagent water (e.g. initial or ongoing precision and recovery sample).

  • If the packed pellet volume is 5 mL, vortex the tube vigorously until pellet is

completely resuspended. Swirl the centrifuge tube gently to reduce any foaming after vortexing. Record the resuspended pellet volume on the bench sheet. Proceed to Section 13.3.

NOTE:  Extra care must be taken with samples containing sand or other gritty material

when vortexing to ensure that the condition of any oocysts and/or cysts in the sample is not compromised.

  • If the packed pellet volume is > 0.5 mL, the concentrate must be separated into

multiple subsamples (a subsample is equivalent to no greater than 0.5 mL of packed pellet material, the recommended maximum amount of particulate material to process through the subsequent purification and examination steps in the method). Use the following formula to determine the total volume required in the centrifuge tube before separating the concentrate into two or more subsamples:

     pellet volume     

total volume (mL) required =                                    x 5 mL

0.5 mL

(For example, if the packed pellet volume is 1.2 mL, the total volume required is 12 mL.) Add reagent water to the centrifuge tube to bring the total volume to the level calculated

                          above.                                                                                                                          

NOTE:  Extra care must be taken with samples containing sand or other gritty material

when vortexing to ensure that the condition of any oocysts in the sample is not compromised.

  • Analysis of entire sample. If analysis of the entire sample is required,

determine the number of subsamples to be processed independently through the remainder of the method:

  • Calculate number of subsamples: Divide the total

volume in the centrifuge tube by 5 mL and round up to the nearest integer (for example, if the resuspended volume in Section 13.2.4 is 12 mL, then the number of

December 2005                                        46

subsamples would be 12 mL / 5 mL = 2.4, rounded = 3 subsamples).

13.2.4.1.2                                  Determine volume of resuspended concentrate per

subsample. Divide the total volume in the centrifuge tube by the calculated number of subsamples (for example, if the resuspended volume in Section 13.2.4 is 12 mL, then the volume to use for each subsample = 12 mL / 3 subsamples = 4 mL).

  • Process subsamples through IMS. Vortex the tube

vigorously for 10 to 15 seconds to completely resuspend the pellet. Record the resuspended pellet volume on the bench sheet. Proceed immediately to Section 13.3, and transfer aliquots of the resuspended concentrate equivalent to the volume in the previous step to multiple, flat-sided sample tubes in Section 13.3.2.1. Process the sample as multiple, independent subsamples from Section

13.3 onward, including the preparation and examination of separate slides for each aliquot. Record the volume of resuspended concentrate transferred to IMS on the bench sheet (this will be equal to the volume recorded in Section 13.2.4). Also record the number of subsamples processed independently through the method on the bench sheet.

  • Analysis of partial sample. If not all of the concentrate will be

examined, vortex the tube vigorously for 10 to 15 seconds to completely resuspend the pellet. Record the resuspended pellet volume on the bench sheet. Proceed immediately to Section 13.3, and transfer one or more 5- mL aliquots of the resuspended concentrate to one or more flat-sided sample tubes in Section 13.3.2.1. Record the volume of resuspended concentrate transferred to IMS on the bench sheet. To determine the volume analyzed, calculate the percent of the concentrate examined using the following formula:

    total volume of resuspended concentrate transferred to IMS 

percent examined =                                                                                           x 100%

total volume of resuspended concentrate in Section 13.2.4

Then multiply the volume filtered (Section 12.2.5.2) by this percentage to determine the volume analyzed.

  • IMS procedure (adapted from Reference 13)

NOTE: The IMS procedure should be performed on a bench top with all materials at room temperature, ranging from 15°C to 25°C.

  • Preparation and addition of reagents
    • Prepare a 1X dilution of SL-buffer-A from the 10X SL-buffer-A (clear,

colorless solution) supplied. Use reagent water (demineralized; Section 7.3) as the diluent. For every 1 mL of 1X SL-buffer-A required, mix 100

µL of 10X SL-buffer-A and 0.9 mL diluent water. A volume of 1.5 mL of 1X SL-buffer-A will be required per sample or subsample on which the Dynal IMS procedure is performed.

47                                                      December 2005

 

  • For each 10mL sample or subsample (Section 13.2) to be processed

through IMS, add 1 mL of the 10X SL-buffer-A (supplied—not the diluted 1X SL-buffer-A) to a flat-sided tube (Section 6.5.4).

  • For each subsample, add 1 mL of the 10X SL-buffer-B (supplied— magenta solution) to the flat-sided tube containing the 10X SL-buffer-A.
  • Oocyst and cyst capture
    • Use a graduated, 10-mL pipette that has been pre-rinsed with elution

buffer to transfer the water sample concentrate from Section 13.2 to the flat-sided tube(s) containing the SL-buffers. If all of the concentrate is used, rinse the centrifuge tube twice with reagent water and add the rinsate to the flat-sided tube containing the concentrate (or to the tube containing the first subsample, if multiple subsamples will be processed). Each of the two rinses should be half the volume needed to bring the total volume in the flat-sided sample tube to 12 mL (including the buffers added in Sections 13.3.1.2 and 13.3.1.3). (For example, if the tube contained 1 mL of SL-buffer-A and 1 mL of SL-buffer-B, and 5 mL of sample was transferred after resuspension of the pellet, for a total of 7 mL, the centrifuge tube would be rinsed twice with 2.5 mL of reagent water to bring the total volume in the flat-sided tube to 12 mL.) Visually inspect the centrifuge tube after completing the transfer to ensure that no concentrate remains. If multiple subsamples will be processed, bring the volume in the remaining flat-sided tubes to 12 mL with reagent water.

Label the flat-sided tube(s) with the sample number (and subsample letters).

  • Vortex the Dynabeads®Crypto-Combo vial from the IMS kit for

approximately 10 seconds to suspend the beads. Ensure that the beads are fully resuspended by inverting the sample tube and making sure that there is no residual pellet at the bottom.

  • Add 100 µL of the resuspended Dynabeads®Crypto-Combo (Section

13.3.2.2) to the sample tube(s) containing the water sample concentrate and SL-buffers.

  • Vortex the Dynabeads®Giardia-Combo vial from the IMS kit for

approximately 10 seconds to suspend the beads. Ensure that the beads are fully resuspended by inverting the tube and making sure that there is no residual pellet at the bottom.

  • Add 100 µL of the resuspended Dynabeads®Giardia-Combo (Section

13.3.2.4) to the sample tube(s) containing the water sample concentrate, Dynabeads®Crypto-Combo, and SL-buffers.

  • Affix the sample tube(s) to a rotating mixer and rotate at approximately 18 rpm for 1 hour at room
  • After rotating for 1 hour, remove each sample tube from the mixer and

place the tube in the magnetic particle concentrator (MPC®-1 or MPC®-

6) with flat side of the tube toward the magnet.

  • Without removing the sample tube from the MPC®-1, place the magnet

side of the MPC®-1 downwards, so the tube is horizontal and the flat side of the tube is facing down.

  • Gently rock the sample tube by hand end-to-end through approximately 90°, tilting the cap-end and base-end of the tube up and down in

December 2005                                        48

Continue the tilting action for 2 minutes with approximately one tilt per second.

  • Ensure that the tilting action is continued throughout this period to

prevent binding of low-mass, magnetic or magnetizable material. If the sample in the MPC®-1 is allowed to stand motionless for more than 10 seconds, remove the flat-sided tube from the MPC®-1, shake the tube to resuspend all material, replace the sample tube in the MPC®-1 and repeat Section 13.3.2.9 before continuing to Section 13.3.2.11.

  • Return the MPC®-1 to the upright position, sample tube vertical, with

cap at top. Immediately remove the cap and, keeping the flat side of the tube on top, pour off all of the supernatant from the tube held in the MPC®-1 into a suitable container. Do not shake the tube and do not remove the tube from MPC®-1 during this step. Allow more supernatant to settle; aspirate additional supernatant with pipette.

  • Remove the sample tube from the MPC®-1 and resuspend the sample in

0.5 mL 1X SL-buffer-A (prepared from 10X SL-buffer-A stock—supplied). Mix very gently to resuspend all material in the tube. Do not vortex.

  • Quantitatively transfer (transfer followed by two rinses) all the liquid

from the sample tube to a labeled, 1.5-mL microcentrifuge tube. Use 0.5 mL of 1X SL-buffer-A to perform the first rinse and 0.5 mL of 1X SL- buffer-A for the second rinse.  Allow the flat-sided sample tube to sit for  a minimum of 1 minute after transfer of the second rinse volume, then use a pipette to collect any residual volume that drips down to the bottom of the tube to ensure that as much sample volume is recovered as possible.

Ensure that all of the liquid and beads are transferred.

  • Place the microcentrifuge tube into the second magnetic particle concentrator (MPC®-M or MPC®-S), with its magnetic strip in
  • Without removing the microcentrifuge tube from MPC®-M, gently

rock/roll the tube through 180° by hand. Continue for approximately 1 minute with approximately one 180° roll/rock per second. At the end of this step, the beads should produce a distinct brown dot at the back of the tube.

  • Immediately aspirate the supernatant from the tube and cap held in the

MPC®-M. If more than one sample is being processed, conduct three 90° rock/roll actions before removing the supernatant from each tube. Take care not to disturb the material attached to the wall of the tube adjacent to the magnet. Do not shake the tube. Do not remove the tube from MPC®- M while conducting these steps.

  • Dissociation of beads/oocyst/cyst complex

NOTE:  Two acid dissociations are required.

  • Remove the magnetic strip from the MPC®-M.
  • Add 50 µL of 1 N HCl, then vortex at the highest setting for approximately 50 seconds.

NOTE: The laboratory must use 0.1-N standards purchased directly from a vendor, rather than adjusting the normality in-house.

 

 

 

49                                                      December 2005

 

  • Place the tube in the MPC®-M without the magnetic strip in place and

allow to stand in a vertical position for at least 10 minutes at room temperature.

  • Vortex vigorously for approximately 30
  • Ensure that all of the sample is at the base of the tube. Place the microcentrifuge tube in the MPC®-M.
  • Replace magnetic strip in MPC®-M and allow the tube to stand

undisturbed for a minimum of 10 seconds.

  • Prepare a well slide for sample screening and label the
  • Add 5 µL of 0 N NaOH to the sample wells of two well slides (add 10

µL to the sample well of one well slide if the volume from the two required dissociations will be added to the same slide).

NOTE: The laboratory must use 1.0-N standards purchased directly from a vendor rather than adjusting the normality in-house.

  • Without removing the microcentrifuge tube from the MPC®-M, transfer

all of the sample from the microcentrifuge tube in the MPC®-M to the sample well with the NaOH. Do not disturb the beads at the back wall of the tube. Ensure that all of the fluid is transferred.

  • Do not discard the beads or microcentrifuge tube after transferring the

volume from the first acid dissociation to the well slide. Perform the steps in Sections 13.3.3.1 through 13.3.3.9 a second time. The volume from the second dissociation can be added to the slide containing the volume from the first dissociation, or can be applied to a second slide.

NOTE: The wells on Dynal Spot-On slides are likely to be too small to accommodate the volumes from both dissociations.

  • Record the date and time the purified sample was applied to the slide(s).
  • Air-dry the sample on the well slide(s). Because temperature and

humidity vary from laboratory to laboratory, no minimum time is specified. However, the laboratory must take care to ensure that the sample has dried completely before staining to prevent losses during the rinse steps. A slide warmer set at 35°C to 42°C also can be used.

  • Tips for minimizing carry-over of debris onto microscope slides after IMS
  • Make sure the resuspended pellet is fully homogenized before placing the tube in the MPC®-1 or MPC®-M to avoid trapping “clumps” or a dirty layer between the beads and the side of the
  • When using the MPC®-1 magnet, make sure that the tube is snugged flat against the magnet. Push the tube flat if necessary. Sometimes the magnet is not flush with the outside of the holder and, therefore, the attraction between the beads and the magnet is not as strong as it should be. However, it can be difficult to determine this if you do not have more than one MPC®-1 to make
  • After the supernatant has been poured off at Section 13.3.2.11, leave the tube in the MPC®-1 and allow time for any supernatant remaining in the tube to settle down to the bottom. Then aspirate the settled supernatant and associated particles from the bottom of the tube. The same can be done at Section 13.3.2.16 with the microcentrifuge

December 2005                                        50

  • An additional rinse can also be performed at Section 13.3.2.11. After the supernatant has been poured off and any settled material is aspirated off the bottom, leave the tube in the MPC®-1 and add an additional 10 mL of reagent water or PBS to the tube and repeat Sections 13.3.2.9 and 13.3.2.11. Although labs have reported successfully using this technique to reduce carryover, because the attraction between the MPC®-1 and the beads is not as great as the attraction between the MPC®-M and the beads,  the chances would be greater for loss of cysts and oocysts doing the rinse at this step instead of at Section 3.2.16.
  • After the supernatant has been aspirated from the tube at Section 13.3.2.16, add 0.1 mL of PBS, remove the tube from the MPC®-M, and resuspend. Repeat Sections

13.3.2.15 and 13.3.2.16.

  • Use a slide with the largest diameter well available to spread out the sample as much as

14.0            Sample Staining                                                                                  

NOTE: The sample must be stained within 72 hours of application of the purified sample to the slide.

  • Prepare positive and negative
    • For the positive control, pipette 10 µL of positive antigen or 200 to 400 intact oocysts and 200 to 400 cysts to the center of a
    • For the negative control, pipette 50 µL of PBS (Section 7.4.2.1) into the center of a well

and spread it over the well area with a pipette tip.

  • Air-dry the control slides (see Section 13.3.3.12 for guidance).

NOTE:  If the laboratory has a large batch of slides that will be examined over several

days, and is concerned that a single positive control may fade, due to multiple examinations, the laboratory should prepare multiple control slides with the batch of field slides and alternate between the positive controls when performing the positive control check.

  • Follow manufacturer’s instructions in applying stain to
  • Place the slides in a humid chamber in the dark and incubate at room temperature for approximately 30 minutes. The humid chamber consists of a tightly sealed plastic container containing damp paper towels on top of which the slides are
  • Remove slides from humid chamber and allow condensation to evaporate, if
  • Apply one drop of wash buffer (prepared according to the manufacturer’s instructions [Section 7.6]) to each well. Tilt each slide on a clean paper towel, long edge Gently aspirate the excess detection reagent from below the well using a clean Pasteur pipette or absorb with paper towel or other absorbent material placed at edge of slide. Avoid disturbing the sample.
  • Apply 50 µL of 4′,6-diamidino-2-phenylindole (DAPI) staining solution (Section 7.7.2) to each well. Allow to stand at room temperature for a minimum of 1 minute. (The solution concentration may be increased up to 1 µg/mL if fading/diffusion of DAPI staining is encountered, but the staining solution must be tested first on expendable environmental samples to confirm that staining intensity is )
  • Apply one drop of wash buffer (prepared according to the manufacturer’s instructions [Section 7.6]) to each well. Tilt each slide on a clean paper towel, long edge Gently aspirate the excess DAPI staining solution from below the well using a clean Pasteur pipette or absorb with paper towel or other absorbent material placed at edge of slide. Avoid disturbing the sample.

51                                                      December 2005

 

 

NOTE: If using the MeriFluor® Cryptosporidium/Giardia (Section 7.6.1), do not allow slides to dry completely.

  • Add mounting medium (Section 7.8) to each
  • Apply a cover slip. Use a tissue to remove excess mounting fluid from the edges of the coverslip. Seal the edges of the coverslip onto the slide using clear nail
  • Record the date and time that staining was completed on the bench sheet. If slides will not be read immediately, store in a humid chamber in the dark between 1°C and 10°C until ready for examination.

15.0            Examination                                                                                        

NOTE:  Although immunofluorescence assay (FA) and 4′,6-diamidino-2-phenylindole

(DAPI) and differential interference contrast (DIC) microscopy examination should be performed immediately after staining is complete, laboratories have up to 168 hours (7 days) from completion of sample staining to complete the examination and verification of samples. However, if fading/diffusion of FITC or DAPI fluorescence is noticed, the laboratory must reduce this holding time. In addition the laboratory may adjust the concentration of the DAPI staining solution (Sections 7.7.2) so that fading/diffusion does not occur.

  • Scanning technique: Scan each well in a systematic fashion. An up-and-down or a side-to-side scanning pattern may be used (Figure 4).
  • Examination using immunofluorescence assay (FA), 4′,6-diamidino-2-phenylindole (DAPI) staining characteristics, and differential interference contrast (DIC) microscopy. The minimum

            magnification requirements for each type of examination are noted below.                               

NOTE: All characterization (DAPI and DIC) and size measurements must be determined using 1000X magnification and reported to the nearest 0.5 µm.

Record examination results for Cryptosporidium oocysts on a Cryptosporidium examination form; record examination results for Giardia cysts on a Giardia  examination results form. All organisms that meet the criteria specified in Sections 15.2.2 and 15.2.3, less atypical organisms specifically identified as non-target organisms by DIC or DAPI (e.g. possessing spikes, stalks, appendages, pores, one or two large nuclei filling the cell, red fluorescing chloroplasts, crystals, spores, etc), must be reported.

  • Positive and negative staining control. Positive and negative staining controls must be acceptable before proceeding with examination of field sample
    • Each analyst must characterize a minimum of three Cryptosporidium

oocysts and three Giardia cysts on the positive staining control slide before examining field sample slides. This characterization must be performed by each analyst during each microscope examination session. FITC examination must be conducted at a minimum of 200X total magnification, DAPI examination must be conducted at a minimum of 400X, and DIC examination and size measurements must be conducted at a minimum of 1000X. Size, shape, and DIC and DAPI characteristics of three Cryptosporidium oocysts and three Giardia cysts must be recorded by the analyst on a microscope log. The analyst also must indicate on each sample examination form whether the positive staining control was acceptable.

December 2005                                        52

  • Examine the negative staining control to confirm that it does not contain

any oocysts or cysts (Section 14.1). Indicate on each sample examination form whether the negative staining control was acceptable.

  • If the positive staining control contains oocysts and cysts within the

expected range and at the appropriate fluorescence for both FA and DAPI, and the negative staining control does not contain any oocysts or cysts (Section 14.1), proceed to Sections 15.2.2 and 15.2.3.

  • Sample examination—Cryptosporidium
    • FITC examination (the analyst must use a minimum of 200X total

magnification). Use epifluorescence to scan the entire well for apple- green fluorescence of oocyst and cyst shapes. When brilliant apple-green fluorescing ovoid or spherical objects 4 to 6 µm in diameter are observed with brightly highlighted edges, increase magnification to 400X and switch the microscope to the UV filter block for DAPI (Section 15.2.2.2), then to DIC (Section 15.2.2.3) at 1000X.

  • DAPI fluorescence examination (the analyst must use a minimum of

400X total magnification). Using the UV filter block for DAPI, the object will exhibit one of the following characteristics:

  • Light blue internal staining (no distinct nuclei) with a green rim
  • Intense blue internal staining
  • Up to four distinct, sky-blue nuclei

Look for atypical DAPI fluorescence, e.g., more than four stained nuclei, size of stained nuclei, and wall structure and color. Record oocysts in category (a) as DAPI-negative; record oocysts in categories (b) and (c) as DAPI-positive.

  • DIC examination (the analyst must use a minimum of 1000X total

magnification [oil immersion lens]). Using DIC, look for external or internal morphological characteristics atypical of Cryptosporidium oocysts (e.g., spikes, stalks, appendages, pores, one or two large nuclei filling the cell, red fluorescing chloroplasts, crystals, spores, etc.) (adapted from Reference 20.10). If atypical structures are not observed, then categorize each apple-green fluorescing object as:

  • An empty Cryptosporidium oocyst
  • Cryptosporidium oocyst with amorphous structure
  • Cryptosporidium oocyst with internal structure (one to four sporozoites/oocyst)

Using 1000X total magnification, record the shape, measurements (to the nearest 0.5 µm), and number of sporozoites (if applicable) for each apple- green fluorescing object meeting the size and shape characteristics.

Although not a defining characteristic, surface oocyst folds may be observed in some specimens.

  • A positive result is a Cryptosporidium oocyst which exhibits typical IFA

fluorescence, typical size and shape and exhibits nothing atypical on IFA, DAPI fluorescence, or DIC microscopy. A positive result must be characterized and assigned to one of the DAPI and DIC categories in Sections 15.2.2.2 and 15.2.2.3.

  • Sample examination—Giardia
    • FITC examination (the analyst must use a minimum of 200X total magnification). When brilliant apple-green fluorescing round to ovoid

53                                                      December 2005

 

objects (8 – 18 µm long by 5 – 15 µm wide) are observed with brightly highlighted edges, increase magnification to 400X and switch the microscope to the UV filter block for DAPI (Section 15.2.3.2) then to DIC (Section 15.2.3.3) at 1000X.

  • DAPI fluorescence examination (the analyst must use a minimum of

400X total magnification). Using the UV filter block for DAPI, the object will exhibit one or more of the following characteristics:

  • Light blue internal staining (no distinct nuclei) and a green rim
  • Intense blue internal staining
  • Two to four sky-blue nuclei

Look for atypical DAPI fluorescence, e.g., more than four stained nuclei, size of stained nuclei, and wall structure and color. Record cysts in category (a) as DAPI negative; record cysts in categories (b) and (c) as DAPI positive.

  • DIC examination (the analyst must use a minimum of 1000X total

magnification [oil immersion lens]). Using DIC microscopy, look for external or internal morphological characteristics atypical of Giardia cysts (e.g., spikes, stalks, appendages, pores, one or two large nuclei filling the cell, red fluorescing chloroplasts, crystals, spores, etc.) (adapted from Reference 20.10). If atypical structures are not observed, then categorize each object meeting the criteria specified in Sections

15.2.3.1 through 15.2.3.3 as one of the following, based on DIC examination:

  • An empty Giardia cyst
  • Giardia cyst with amorphous structure
  • Giardia cyst with one type of internal structure (nuclei, median body, or axonemes), or
  • Giardia cyst with more than one type of internal structure

Using 1000X total magnification, record the shape, measurements (to the nearest 0.5 µm), and number of nuclei and presence of median body or axonemes (if applicable) for each apple-green fluorescing object meeting the size and shape characteristics.

  • A positive result is a Giardia cyst which exhibits typical IFA

fluorescence, typical size and shape and exhibits nothing atypical on IFA, DAPI fluorescence, or DIC microscopy. A positive result must be characterized and assigned to one of the DAPI and DIC categories in Section 15.2.3.2 and 15.2.3.3.

  • Record the date and time that sample examination was completed on the examination form.
  • Report Cryptosporidium and Giardia concentrations as oocysts/L and cysts/L,

respectively.

  • Record analyst name

16.0            Analysis of Complex Samples

  • Some samples may contain high levels (>1000/L) of oocysts and cysts and/or interfering organisms, substances, or materials. Some samples may clog the filter (Section 12.0); others will not allow separation of the oocysts and cysts from the retentate or eluate; and others may contain materials that preclude or confuse microscopic

December 2005                                        54

  • If the sample holding time has not been exceeded and a full-volume sample cannot be filtered, dilute an aliquot of sample with reagent water and filter this smaller aliquot (Section 12.0). This dilution must be recorded and reported with the
  • If the holding times for the sample and for microscopic examination of the cleaned up retentate/eluate have been exceeded, the site should be re-sampled. If this is not possible, the results should be qualified
  • Some samples may adhere to the centrifuge tube walls. The use of siliconized or low-adhesion centrifuge tubes (Fisherbrand siliconized/low retention microcentrifuge tubes, 02-681-320 or equivalent) may reduce adhesion. Alternately, rinse centrifuge tubes with PBST elution buffer or Sigmacote® prior to

17.0            Method Performance

  • Method acceptance criteria are shown in Tables 3 and 4 in Section 21.0. The initial and ongoing precision and recovery criteria are based on the results of spiked reagent water samples analyzed during the Information Collection Rule Supplemental Surveys (Reference 20.11). The matrix spike and matrix spike duplicate criteria are based on spiked source water data generated during the interlaboratory validation study of Method 1623 involving 11 laboratories and 11 raw surface water matrices across the U.S. (Reference 14).

NOTE:  Some sample matrices may prevent the MS acceptance criteria in Tables 3 and 4

to be met. An assessment of the distribution of MS recoveries across 430 MS samples from 87 sites during the ICR Supplemental Surveys is provided in Table 5.

 

18.0            Pollution Prevention

  • The solutions and reagents used in this method pose little threat to the environment when recycled and managed
  • Solutions and reagents should be prepared in volumes consistent with laboratory use to minimize the volume of expired materials that need to be

19.0            Waste Management

  • It is the laboratory’s responsibility to comply with all federal, state, and local regulations govern- ing waste management, particularly the biohazard and hazardous waste identification rules and land disposal restrictions, and to protect the air, water, and land by minimizing and controlling all releases from fume hoods and bench operations. Compliance with all sewage discharge permits and regulations is also required. An overview of these requirements can be found in the Environmental Management Guide for Small Laboratories (EPA 233-B-98-001).
  • Samples, reference materials, and equipment known or suspected to have viable oocysts or cysts attached or contained must be sterilized prior to
  • For further information on waste management, consult The Waste Management Manual for Laboratory Personnel and Less is Better: Laboratory Chemical Management for Waste Reduction, both available from the American Chemical Society’s Department of Government Relations and Science Policy, 1155 16th Street N.W., Washington, D.C.

20.0            References

  • Morgan-Ryan, UM, A. Fall, L.A. Ward, N. Hijjawi, Sulaiman, R. Fayer, R.C.Thompson, M. Olson, A. Lal, L. Xiao. 2002. Cryptosporidium hominis n. sp. (Apicomplexa: Cryptosporidiidae from Homo sapiens). Journal Eukaryot Microbiol 49(6):433-450.
  • Adam, R.D. 2001. Biology of Giardia lamblia. Clinical Microbiology Review 14(3):447-475.

55                                                      December 2005

 

  • Rodgers, Mark R., Flanigan, Debbie J., and Jakubowski, Walter, 1995. Applied and Environmental Microbiology 61 (10), 3759-3763.
  • Fleming, Diane O., et al.(eds.), Laboratory Safety: Principles and Practices, 2nd edition.1995. ASM Press, Washington, DC
  • “Working with Carcinogens,” DHEW, PHS, CDC, NIOSH, Publication 77-206, (1977).
  • “OSHA Safety and Health Standards, General Industry,” OSHA 2206, 29 CFR 1910 (1976).
  • “Safety in Academic Chemistry Laboratories,” ACS Committee on Chemical Safety (1979).
  • APHA, AWWA, and WEF. 2005. Standard Methods for the Examination of Water and Wastewater; 21th American Public Health Association, American Water Works Association, Washington, D.C.
  • USEPA 2005. Manual for the Certification of Laboratories Analyzing Drinking Water; Criteria and Procedures; Quality Assurance. Fifth Edition. EPA 815-R-05-004. Office of Ground Water and Drinking Water, U.S. Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH
  • ICR Microbial Laboratory Manual, EPA/600/R-95/178, National Exposure Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, 26 Martin Luther King Drive, Cincinnati, OH 45268 (1996).
  • Connell, K., C.C. Rodgers, H.L. Shank-Givens, J Scheller, L Pope, and K. Miller, 2000.

Building a Better Protozoa Data Set. Journal AWWA, 92:10:30.

  • “Envirochek™ Sampling Capsule,” PN 32915, Gelman Sciences, 600 South Wagner Road, Ann Arbor, MI 48103-9019 (1996).
  • “Dynabeads® GC-Combo,” Dynal Microbiology R&D, P.O. Box 8146 Dep., 0212 Oslo, Norway (September 1998, Revision no. 01).
  • Results of the Interlaboratory Method Validation Study for Determination of Cryptosporidium and Giardia Using USEPA Method 1623, EPA-821-R-01-028. Office of Water, Office of Science and Technology, Engineering and Analysis Division, Washington, DC (2001).
  • Implementation and Results of the Information Collection Rule Supplemental Surveys. EPA-815-R-01-003. Office of Water, Office of Ground Water and Drinking Water, Standards and Risk Management Division, Washington, DC (2001).
  • Connell, K., J. Scheller, K. Miller, and C.C. Rodgers, 2000. Performance of Methods 1622 and 1623 in the ICR Supplemental Surveys. Proceedings, American Water Works Association Water Quality Technology Conference, November 5 – 9, 2000, Salt Lake City,

December 2005                                        56

21.0  Tables and Figures

Table 1. Method Holding Times (See Section 8.2 for details)

Sample Processing Step Maximum Allowable Time between Breaks

(Samples should be processed as soon as possible)

Collection
Filtration
‘ Up to 96 hours are permitted between sample collection (if shipped to the laboratory as a bulk sample) or filtration (if filtered in the field) and initiation of elution
Elution  

 

 

These steps must be completed in 1 working day

Concentration
Purification
Application of purified sample to slide
Drying of sample
‘ Up to 72 hours are permitted from application of the purified sample to the slide to staining
Staining
‘ Up to 7 days are permitted between sample staining and examination
Examination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57                                                      December 2005

 

Table 2.      Tier 1 and Tier 2 Validation/Equivalency Demonstration Requirements

Test Description Tier 1 modification(1) Tier 2 modification(2)
IPR

(Section 9.4)

4 replicates of spiked reagent water Required. Must be accompanied by a method blank.  

Required per laboratory

Method blank (Section 9.6) Unspiked reagent water  

Required

 

Required per laboratory

 

MS

(Section 9.5.1)

 

 

Spiked matrix water

Required on each water to which the modification will be applied and on every 20th sample of that water thereafter. Must be accompanied by an unspiked field sample collected at the same time as the MS sample  

 

Not required

MS/MSD

(Section 9.5)

2 replicates of spiked matrix water Recommended, but not required. Must be accompanied by an unspiked field sample collected at the same time as the MS sample Required per laboratory. Each laboratory must analyze a different water.
  • If a modification will be used only in one laboratory, these tests must be performed and the results must meet all of the QC acceptance criteria in the method (these tests also are required the first time a laboratory uses the validated version of the method)
  • If nationwide approval of a modification is sought for one type of water matrix (such as surface water), a minimum of 3 laboratories must perform the tests and the results from each lab individually must meet all QC acceptance criteria in the method. If more than 3 laboratories are used in a study, a minimum of 75% of the laboratories must meet all QC acceptance

NOTE:  The initial precision and recovery and ongoing precision and recovery (OPR)

acceptance criteria listed in Tables 3 and 4 are based on results from 293 Cryptosporidium OPR samples and 186 Giardia OPR samples analyzed by six laboratories during the Information Collection Rule Supplemental Surveys (Reference 20.15). The matrix spike acceptance criteria are based on data generated through interlaboratory validation of Method 1623 (Reference 20.14).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

December 2005                                        58

Table 3. Quality Control Acceptance Criteria for Cryptosporidium

Performance test Section Acceptance criteria
Initial precision and recovery 9.4
Mean recovery (percent) 9.4.3 24 – 100
Precision (as maximum relative standard deviation) 9.4.3 55
Ongoing precision and recovery (percent) 9.7 11 – 100
Matrix spike/matrix spike duplicate (for method modifications) 9.5
Mean recovery1, 2 (as percent) 9.5.2.2 13 – 111
Precision (as maximum relative percent difference) 9.5.2.3 61
  • The acceptance criteria for mean MS/MSD recovery serves as the acceptance criteria for MS recovery during routine use of the method (Section 5.1).
  • Some sample matrices may prevent the acceptance criteria from being met. An assessment of the distribution of MS recoveries from multiple MS samples from 87 sites during the ICR Supplemental Surveys is provided in Table 5.

Table 4. Quality Control Acceptance Criteria for Giardia

Performance test Section Acceptance criteria
Initial precision and recovery 9.4
Mean recovery (percent) 9.4.3 24 – 100
Precision (as maximum relative standard deviation) 9.4.3 49
Ongoing precision and recovery (percent) 9.7 14 – 100
Matrix spike/matrix spike duplicate (for method modifications) 9.5
Mean recovery1,2 (as percent) 9.5.2.2 15 – 118
Precision (as maximum relative percent difference) 9.5.2.3 30
  • The acceptance criteria for mean MS/MSD recovery serves as the acceptance criteria for MS recovery during routine use of the method (Section 5.1).
  • Some sample matrices may prevent the acceptance criteria from being met. An assessment of the distribution of MS recoveries across multiple MS samples from 87 sites during the ICR Supplemental Surveys is provided in Table

59                                                      December 2005

 

Table 5. Distribution of Matrix Spike Recoveries from Multiple Samples Collected from 87 Source Waters During the ICR Supplemental Surveys (Adapted from Reference 20.16)

 

MS Recovery Range

Percent of 430 Cryptosporidium MS Samples in Recovery Range Percent of 270 Giardia MS Samples in Recovery Range
<10% 6.7% 5.2%
>10% – 20% 6.3% 4.8%
>20% – 30% 14.9% 7.0%
>30% – 40% 14.2% 8.5%
>40% – 50% 18.4% 17.4%
>50% – 60% 17.4% 16.3%
>60% – 70% 11.2% 16.7%
>70% – 80% 8.4% 14.1%
>80% – 90% 2.3% 6.3%
>90% 0.2% 3.7%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

December 2005                                        60

 

 

Figure 1.  Hemacytometer Platform Ruling. Squares 1, 2, 3, and 4 are used to count stock suspensions of Cryptosporidium oocysts and Giardia cysts (after Miale, 1967)

 

 

 

 

61                                                      December 2005

 

 

 

Figure 2.  Manner of Counting Oocysts and Cysts in 1

Square mm. Dark organisms are counted and light organisms are omitted (after Miale, 1967).

December 2005                                        62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3a. Filtration Systems for Envirochek™ or Envirochek™HV Capsule (unpressurized source – top, pressurized source – bottom)

 

 

 

 

 

 

 

63                                                      December 2005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3b. Filtration Systems for Filta-Max® filters (unpressurized source – top, pressurized source – bottom)

 

 

 

 

 

 

 

 

 

 

December 2005                                        64

 

 

 

 

 

Figure 4.   Methods for Scanning a Well Slide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65                                                      December 2005

 

22.0            Glossary of Definitions and Purposes

 

These definitions and purposes are specific to this method but have been conformed to common usage as much as possible.

  • Units of weight and measure and their abbreviations
    • Symbols

°C        degrees Celsius

µL        microliter

<          less than

>          greater than

%         percent

  • Alphabetical characters cm centimeter

g          gram

G         acceleration due to gravity hr            hour

ID        inside diameter

  1. inch

L          liter

m         meter

MCS    microscope cleaning solution mg            milligram

mL       milliliter

mm      millimeter

mM      millimolar

N         normal; gram molecular weight of solute divided by hydrogen equivalent of solute, per liter of solution

RSD     relative standard deviation

sr               standard deviation of recovery X            mean percent recovery

  • Definitions, acronyms, and abbreviations (in alphabetical order)

Analyst—The analyst should have at least 2 years of college in microbiology or equivalent or closely related field. The analyst also should have a minimum of 6 months of continuous bench experience with Cryptosporidium and IFA microscopy. The analyst should have a minimum of 3 months experience using EPA Method 1622 and/or EPA Method 1623 and should have successfully analyzed a minimum of 50 samples using EPA Method 1622 and/or EPA Method 1623.

Analyte—A protozoan parasite tested for by this method. The analytes in this method are

Cryptosporidium and Giardia.

Axoneme—An internal flagellar structure that occurs in some protozoa, such as GiardiaSpironucleous, and Trichonmonas.

Cyst—A phase or a form of an organism produced either in response to environmental conditions or as a normal part of the life cycle of the organism. It is characterized by a thick and environmentally resistant cell wall.

December 2005                                        66

Flow cytometer—A particle-sorting instrument capable of counting protozoa.

Immunomagnetic separation (IMS)—A purification procedure that uses microscopic, magnetically responsive particles coated with an antibodies targeted to react with a specific pathogen in a fluid stream. Pathogens are selectively removed from other debris using a magnetic field.

Initial precision and recovery (IPR)—Four aliquots of spiking suspension analyzed to establish the ability to generate acceptable precision and accuracy. An IPR is performed prior to the first time this method is used and any time the method or instrumentation is modified.

Laboratory blank—See Method blank

Laboratory control sample (LCS)—See Ongoing precision and recovery (OPR) standard

Matrix spike (MS)—A sample prepared by adding a known quantity of organisms to a specified amount of sample matrix for which an independent estimate of target analyte concentration is available. A matrix spike is used to determine the effect of the matrix on a method’s recovery efficiency.

May—This action, activity, or procedural step is neither required nor prohibited. May not—This action, activity, or procedural step is prohibited.

Median bodies—Prominent, dark-staining, paired organelles consisting of microtubules and found in the posterior half of Giardia. In G. intestinalis (from humans), these structures often have a claw-hammer shape, while in G. muris (from mice), the median bodies are round.

Method blank—An aliquot of reagent water that is treated exactly as a sample, including exposure to all glassware, equipment, solvents, and procedures that are used with samples. The method blank is used to determine if analytes or interferences are present in the laboratory environment, the reagents, or the apparatus.

Must—This action, activity, or procedural step is required. Negative control—See Method blank

Nucleus—A membrane-bound organelle containing genetic material. Nuclei are a prominent internal structure seen both in Cryptosporidium oocysts and Giardia cysts. In Cryptosporidium oocysts, there is one nucleus per sporozoite. One to four nuclei can be seen in Giardia cysts.

Oocyst—The encysted zygote of some sporozoa; e.g., Cryptosporidium. The oocyst is a phase or form of the organism produced as a normal part of the life cycle of the organism. It is characterized by a thick and environmentally resistant outer wall.

Ongoing precision and recovery (OPR) standard—A method blank spiked with known quantities of analytes. The OPR is analyzed exactly like a sample. Its purpose is to assure that the results produced by the laboratory remain within the limits specified in this method for precision and recovery.

Oocyst and cyst spiking suspension—See Spiking suspension Oocyst and cyst stock suspension—See Stock suspension

67                                                      December 2005

 

Positive control—See Ongoing precision and recovery standard

Principal analyst—The principal analyst (may not be applicable to all monitoring programs) should have a BS/BA in microbiology or closely related field and a minimum of 1 year of continuous bench experience with Cryptosporidium and IFA microscopy. The principal analyst also should have a minimum of 6 months experience using EPA Method 1622 and/or EPA Method 1623 and should have analyzed a minimum of 100 samples using EPA Method 1622 and/or EPA Method 1623.

PTFE—Polytetrafluoroethylene

Quantitative transfer—The process of transferring a solution from one container to another using a pipette in which as much solution as possible is transferred, followed by rinsing of the walls of the source container with a small volume of rinsing solution (e.g., reagent water, buffer, etc.), followed by transfer of the rinsing solution, followed by a second rinse and transfer.

Reagent water—Water demonstrated to be free from the analytes of interest and potentially interfering substances at the method detection limit for the analyte.

Reagent water blank—see Method blank

Relative standard deviation (RSD)—The standard deviation divided by the mean times 100. RSD—See Relative standard deviation

Should—This action, activity, or procedural step is suggested but not required.

Spiking suspension—Diluted stock suspension containing the organism(s) of interest at a concentration appropriate for spiking samples.

Sporozoite—A motile, infective stage of certain protozoans; e.g., Cryptosporidium. There are four sporozoites in each Cryptosporidium oocyst, and they are generally banana-shaped.

Stock suspension—A concentrated suspension containing the organism(s) of interest that is obtained from a source that will attest to the host source, purity, authenticity, and viability of the organism(s).

Technician—The technician filters samples, performs centrifugation, elution, concentration, and purification using IMS, and places purified samples on slides for microscopic examination, but does not perform microscopic protozoan detection and identification. No minimum education or experience requirements with Cryptosporidium and IFA microscopy apply to the technician. The technician should have at least 3 months of experience in filter extraction and processing of protozoa samples by EPA Method 1622/1623 and should have successfully processed a minimum of 50 samples using EPA Method 1622/1623.

December 2005                                        68

A Brief Guide To Cryptosporidium & Giardia

Cyptosporidium is a microscopic protozoan parasite found in surface waters such as rivers and lakes that are used as drinking water supplies. A number of waterborne disease outbreaks in the U.S. and other countries have been attributed to Cryptosporidium, including a 1993 outbreak of over 400,000 cases in Milwaukee, Wisconsin.
Like Cryptosporidium, Giardia is a protozoan parasite found in surface waters. Giardia can cause gastrointestinal disease. Unlike Cryptosporidium infections, it is treatable with chemotherapy.
Interpretation of Cryptosporidium, Giardia positive results is difficult since the protozoans detected may be dead, the Cryptosporidium or Giardia detected may not be infective to humans, or the monitoring recoveries of the parasites are low. Only intact cysts or oocysts have the potential to be infective, however, the presence of even an empty Cryptosporidium or Giardia indicates infiltration into the water supply.
Environmental Associates Ltd. (EAL) offers testing for Cryptosporidium and Giardia by EPA Method 1623.  With protozoan analysts surpassing national performance in recovery and identification of Cryptosporidium and Giardia during the ICR and LT2 performance evaluations, EAL is uniquely qualified for water source monitoring.  Please call EAL to discuss your monitoring and source water assessment needs.

 

EPA LT2 Envirochek™ Field Filtration for Cryptosporidium – Appendix G

Appendix G

 

Envirochek™ Field Filtration for Cryptosporidium

Procedure for Field-Filtering Samples for Cryptosporidium Analysis Using the Pall Life Sciences Envirochek™ or Envirochek™ HV Capsules

 


 

1.0      Materials

The following materials should be available before collecting sample:

  • Several pairs of new, powder-free latex gloves
  • Sample collection form (Appendix F)
  • Pall Life Sciences Envirochek™ or Envirochek™ HV capsule (recommend that two capsules be kept on hand in case the first one clogs prior to filtering 10 L)
  • Sanitary $30 L carboy (if sample is not from a pressurized source)
  •  Stopwatch
  •  Sample label
  • Cooler, approximately 16-quart
  • Temperature monitoring device (e.g., thermometer vial, Thermochron™ iButton, or equivalent) (if measuring temperature during shipment)
  • Two large plastic trash bags
  • One 8-lb bag of ice or gel ice packs
  • Three gallon size ziplock bags
  • Strapping tape
  • Two self-adhesive plastic airbill sleeves
  • Airbill for shipment
  • The following items may be purchased as a unit for sampling from a vendor or laboratory supplying sampling apparatus for field filtering Cryptosporidium samples:
  • Pump (if sample is not from a pressurized source) – Electric centrifugal or Electric peristaltic pump, or any equivalent pump that can create a flow of approximately 2 L/min
  • Two 0.5-in. X 0.375-in. barbed reducing connectors
  • Five lengths of clean 12.7-mm (0.5-in.) internal-diameter clear, vinyl, laboratory tubing
  • Five pairs of hose clamps fit to tubing
  • One 0.5-in. x 3-in. nipple
  • One coupling to fit 0.5-in. internal diameter tubing
  • One roll teflon tape
  • One 0.5-in. x 0.5-in. x 0.25-in. tee Q  Six 0.5-in. barbed male adapters            One garden hose barbed adapter  Pressure regulator

 

Q Pressure gauge (capsule’s maximum operating pressure, Envirochek™ – 30 PSID, Envirochek™
HV – 60 PSID)
Q Water meter (flow totalizer)
Q Flow rate meter with valve or flow control valve (capsule’s maximum flow rate, Envirochek™ ­
2 L/min, Envirochek™ HV – 4 L/min)
2.0 Collecting the Sample

 

If the sample will be collected from a pressurized source, use the sample collection procedures in Section

2.1. If the sample will be collected from an unpressurized source, use the sample collection procedures in Section 2.2.

 

2.1                          Sample Filtration from a Pressurized Source

  • Before connecting the sampling system to the tap or source, turn on the tap and allow the water to flow for 2 to 3 minutes until the temperature has stabilized or until any debris that has accumulated in the source water lines has cleared and the turbidity in the water becomes visibly uniform. Turn off the
  • Put on a pair of powder-free latex gloves to prevent contamination from outside sources. Any contamination inside the sampling apparatus may bias the final
  • Determine the pressure of the water source with the pressure
  • Assemble the sampling system, minus the Envirochek™ /Envirochek™ HV capsule. In place of the Envirochek™ /Envirochek™ HV capsule, insert a 0.5-in. barbed connector between the outlet tubing from the sample valve or the pressure regulator or gauge and the inlet tubing of the flow totalizer, flow meter or control valve. For high pressure (>30 PSIG for Envirochek™ capsule or

>60 PSIG for Envirochek™ HV capsule) sites, the sampling system should be assembled in the following order, as shown in Figure 1 below:

  • Reinforced influent tubing
  • Pressure regulator
  • Pressure gauge
  • Reinforced inlet tubing
  • Envirochek™ /Envirochek™ HV capsule
  • Reinforced outlet tubing
  • Flow totalizer (mechanical or graduated collection device)
  • Flow rate meter with valve or flow control valve
  • Effluent tubing to drain

Figure 1.Sample System Setup for Collecting Cryptosporidium Samples from a Pressurized Source ( >30 PSIG for Envirochek™ capsule or >60 PSIG for Envirochek™ HV capsule)

 

 

 

For low pressure (1 to 30 PSIG for Envirochek™ capsule or 1 to 60 PSIG for Envirochek™ HV capsule) sites, the sampling system should be assembled at the sample port valve in the following order, as shown in Figure 2 below :

  • Influent tubing
  • Envirochek™ /Envirochek™ HV capsule
  • Outlet tubing
  • Flow rate meter with valve or flow control valve
  • Flow totalizer (mechanical or graduated collection device)
  • Effluent tubing to drain

Figure 2.Sample System Setup for Collecting Cryptosporidium Samples from a Pressurized Source (1 – 30 PSIG for Envirochek™ capsule or 1 – 60 PSIG for Envirochek™ HV capsule)

 

 

 

  • Connect the sampling system, with the connector in place of the Envirochek™ /Envirochek™ HV capsule, to the pressurized water system, using appropriate fittings and
  • Slowly turn the tap to fully open. Allow a minimum of 20 L to flush the system. During this period, perform the following steps:
  • Measuring the flow rate with the flow rate meter or the flow totalizer and a stopwatch, adjust the flow rate to approximately 2 L/min (approximately 0.5 gpm) for the Envirochek™ capsule or 4 L/min (approximately 1.0 gpm) for the Envirochek™ HV capsule. If a flow control valve at the appropriate flow rate is used, no adjustment of the flow rate is necessary. Using the pressure regulator, adjust the pressure to a maximum of 30 PSIG if using the Envirochek™ or 60 PSIG if using the Envirochek™ HV. Observe the system for leaks and take the necessary corrective action if any are
  • Record the following information on the sample collection form (Appendix F):
    • Public water system (PWS) name
    • PWS address
    • Sampler name
    • Sample ID (optional)
    • Public Water System Identification (PWS ID) number
    • Public Water System facility ID number
    • Facility name
    • Sample collection point ID O Sample collection point name            Sample collection date
    • Source water type (optional [but required for E. coli sample forms])
    • Requested analysis (circle Cryptosporidium field sample for routine monitoring sample; circle both “Cryptosporidium field sample” and “Cryptosporidium matrix spike” sample if you are sending an additional sample with the monitoring sample for matrix spike analysis)
  • After the assembly has been flushed, measure the turbidity of the source water and any optional water quality parameters such as temperature, and/or

 

  • Turn off the water at the sample port valve when the flow rate has been adjusted and the system has been

 

  • Record the following information on the capsule label with a waterproof pen:

PWS ID

Facility name

Date of sample collection

 

  • Record the following information on the sample collection form:

Initial meter reading

  • Remove the connector and in its place, install the Envirochek™ /Envirochek™ HV capsule in line, securing the inlet and outlet ends with the appropriate fittings/clamps.

 

 

Note!   Retain the vinyl caps provided with the Envirochek™ /Envirochek™ HV capsule. These caps will be needed to seal the capsule for shipment.

 

  • Slowly turn on the pressurized water source. Adjust the flow rate to approximately 2 L/min for Envirochek™ capsule or 4 L/min for Envirochek™ HV capsule, if necessary. Record the following information on the capsule label or sample collection form:

Start time

 

  • Vent the residual air in the capsule using the bleed valve by turning it counter-clockwise. When the capsule is full of water, close the bleed

 

  • Monitor the water meter. When the targeted volume (actual sample volumes will be selected by the utility, but volumes are typically 10 L [2.64 gal] to 50 L [13.2 gal] and preferred to be consistent between sampling events for each source) has passed through the Envirochek™

/Envirochek™ HV capsule, shut off the water source. Allow the pressure to decrease until the water stops.

 

  • Record the following information on the capsule label and/or sample collection form:

Stop time (when the water was shut off)

Final meter reading

Comments to laboratory, if needed

 

  • With the capsule inlet pointed up, loosen the outlet end of the Envirochek™ /Envirochek™ HV capsule and allow water to drain as much as possible. Water drainage from the capsule through the outlet is acceptable, as the sample has passed through the membrane. Opening the bleed valve during the draining will speed the process. Be sure to close the valve when

 

  • Disconnect the inlet end of the Envirochek™ /Envirochek™ HV capsule, making sure not to spill any of the water remaining in the capsule through the inlet port. This water is part of your sample. Capsule may be shipped with or without residual

 

  • Seal the inlet of the capsule with the vinyl end cap that was previously

 

  • Seal the outlet of the capsule with the vinyl end cap that was previously saved. Place the Envirochek™ /Envirochek™ HV capsule in a plastic ziplock bag for

 

  • Immediately following sample collection, place the bag containing the capsule in a refrigerator to chill prior to packing the shipping cooler for shipment. If no refrigerator is available, and the sample will not be shipped for several hours, place the bag in the shipping cooler with ice to chill. Replace the ice with fresh ice before

 

Note!   Method 1622/1623 requires that the temperature of the sample upon arrival at the laboratory must be #20°C (but not frozen), and the laboratory must begin sample processing within 96 hours of sample collection. If the sample temperature and holding time requirements are not met, then the sample is invalid and must be recollected.

 

2.2                          Sample Filtration Using an Unpressurized Source

  • Put on a pair of powder-free latex gloves to prevent contamination from outside sources. Any contamination inside the sampling apparatus may bias the final

 

  • If sampling from a source of unlimited volume, it may be desirable to pre-flush the sampling system. Assemble the sampling system, minus the Envirochek™ /Envirochek™ HV capsule. In place of the Envirochek™ /Envirochek™ HV capsule, insert a 0.5-in. coupling to connect the influent tubing to the inlet tubing of the pump. The sampling system should be assembled in the following order, as shown in Figure 3 below:

Influent tubing

Envirochek™ /Envirochek™ HV capsule

Outlet tubing

Centrifugal or peristaltic pump

Tubing

Flow rate meter with valve or flow control valve

Flow totalizer (mechanical or graduated collection device)

Effluent tubing to drain

Figure 3.          Sample System Setup for Collecting Cryptosporidium Samples from an Unpressurized Source

 

 

When assembling sample chain, make sure that it is as airtight as possible in order to create a vacuum. To accomplish this, make sure that clamps are used at each connection and that rubber washers are inserted into the hose connections on the inlet and outlet ends of the centrifugal pump.

 

  • Place the inlet end of the inlet tubing into the sample source, away from any walls, bottom, or other environmental

 

  • Turn on the pump and allow a minimum of 20 L to flush the system. If sampling source water from a carboy, continuously refill the carboy as necessary to flush the system. As a recommendation, the carboy should not be removed from the sampling chain and should be refilled using a separate container. Observe the system for leaks and take the necessary corrective action if any are present. During this period, perform the following steps:

 

 

  • Measuring flow rate with the flow rate meter or the flow totalizer and a stopwatch, adjust the flow rate to approximately 2 L/min (approximately 0.5 gpm) for the Envirochek™ capsule or 4 L/min (approximately 1.0 gpm) for the Envirochek™ HV capsule by varying the pump speed or adjusting the valve (if pump is not variable speed). If a flow control valve at the appropriate flow rate is used, no adjustment of the flow rate is

 

  • Record the following information on the sample collection form:
    •          Public water system (PWS) name
    •          PWS address
    •          Sampler name
    •          Sample ID (optional)
    •          Public Water System Identification (PWS ID) number
    •          Public Water System facility ID number
    •          Facility name
    •          Sample collection point ID O Sample collection point name O           Sample collection date
    •          Source water type (optional [but required for E. coli sample forms])
    •          Requested analysis (circle Cryptosporidium field sample for routine monitoring sample; circle both “Cryptosporidium field sample” and “Cryptosporidium matrix spike” sample if you are sending an additional sample with the monitoring sample for matrix spike analysis)

 

  • Turn off the pump when the flow rate has been adjusted and the assembly has been

 

  • Record the following information on the capsule label:

PWS ID

Facility name

Date of sample collection

 

  • Record the following information on the sample collection form:

Initial meter reading

 

  • Install the Envirochek™ /Envirochek™ HV capsule in line, securing the inlet and outlet ends with the appropriate fittings/clamps.

 

Note!   Retain the vinyl caps provided with the Envirochek™ /Envirochek™ HV capsule. These caps will be needed to seal the capsule for shipment.

 

  • Refill the carboy with the sample to be filtered. As a recommendation, the carboy should not be removed from the sampling assembly and should be refilled using a separate

 

  • Turn on the pump. Adjust the flow rate to approximately 2 L/min for the Envirochek™ capsule or 4 L/min for the Envirochek™ HV capsule, if necessary. Record the following information on the capsule label and/or sample collection form:

Start time

 

  • Monitor the water meter continuously refilling the carboy as needed. When the targeted volume (actual sample volumes are selected by the utility, but volumes are typically 10 L [2.64 gal] to 50 L [13.2 gal] and preferred to be consistent between sampling events for each source) is reached, remove tubing from the carboy and then shut off the

 

  • Record the following information on the capsule label and/or sample collection form:

Stop time (when the pump was shut off)

Final meter reading

Comments to laboratory, if needed

 

  • With the capsule inlet pointed up, loosen the outlet end of the Envirochek™ /Envirochek™ HV capsule and allow water to drain as much as possible. Water drainage from the capsule through the outlet is acceptable, as the sample has passed through the membrane. Opening the bleed valve during the draining will speed the process. Be sure to close the valve when

 

  • Disconnect the inlet end of the Envirochek™ /Envirochek™ HV capsule, making sure not to spill any of the water remaining in the capsule through the inlet port. This water is part of your sample. Capsule may be shipped with or without residual

 

  • Seal the inlet of the capsule with the vinyl end cap that was saved

 

  • Seal the outlet of the capsule with the vinyl end cap that was saved previously. Place the Envirochek™ /Envirochek™ HV capsule in a plastic ziplock bag for

 

  • Immediately following sample collection, place the bag containing the capsule in a refrigerator to chill prior to packing the shipping cooler for shipment. If no refrigerator is available, and the sample will not be shipped for several hours, place the bag in the shipping cooler with ice to chill. Replace the ice before

 

Note!   Method 1622/1623 requires that the temperature of the sample upon arrival at the laboratory must be #20°C (but not frozen), and the laboratory must begin sample processing within 96 hours of sample collection. If the sample temperature and holding time requirements are not met, then the sample is invalid and must be recollected.

 

3.0                     Packing the Sample

  • Insert two large plastic trash bags into the shipping cooler to create a double liner. Immediately before packing the cooler, create two 4-pound bags of ice in two separate ziplock bags. To prevent leaks place each ice pack into an additional ziplock bag. Gel packs or blue ice may be used instead of wet ice, as long as the sample is maintained in the appropriate temperature Seal the ziplock bags, expelling as much air as possible, and secure top with tape.

 

Note!   Shipping companies may delay sample shipments if leakage occurs. Double liners and ziplock bags around ice will prevent leakage and delays.

 

  • Place the bag containing the capsule into the shipping container. Wrap the capsule in bubble wrap to prevent freezing. Inflated, empty sample bags can be placed between the capsule and the ice packs to prevent the sample from

 

  • If you will be monitoring sample temperature during shipment, place in the cooler the temperature monitoring device (e.g., extra sample bottle for measuring sample temperature upon receipt at the laboratory, thermometer vial, or Thermochron™ iButton). Seal each liner bag by twisting top of bag and tying in a

 

  • Peel the backing off one of the plastic airbill sleeves and attach the sleeve to the inside of the cooler

Sign and date the sample collection form.

 

Fold the completed sample collection form, and place it inside the plastic sleeve.

 

  • Close the cooler lid, seal the horizontal joints with strapping tape, and secure the lid with tape by taping the cooler at each end, perpendicular to the

 

Note!   Shipping companies may delay sample shipments if leakage occurs. Be sure to seal the cooler joints.

 

  • Peel the backing off of the second airbill sleeve and attach the sleeve to the outside of the cooler lid. Complete the shipping airbill with the laboratory address, billing information, sample weight, and shipping service. Remove the shipper’s copy of the airbill, and place the remainder of the airbill inside the plastic

 

4.0                     Shipping and Tracking

  • Ship samples on the day of collection and use a reliable shipping service for overnight delivery. If samples are not shipped the day of collection, the sample must be maintained between 1°C and 10°C (but not frozen) by chilling in a refrigerator or cooler filled with

 

  • Contact the laboratory to notify them of the sample shipment. Request that the laboratory contact you the next day if the sample is not

 

  • Using the airbill number on the shipper’s copy of the airbill, track the sample shipment using the shipping company’s web page or by contacting the shipping company over the

 

  • If problems are encountered with the shipment, communicate with the shipping company to resolve, and update the laboratory regarding the status of the

EPA Fact Sheet – LT2 Cryptosporidium – Long Term 2 Enhanced Surface Water Treatment Rule

Original PDF from EPA

In the past 30 years, the Safe Drinking Water Act (SDWA) has been highly effective in protecting public health and has also evolved to respond to new and emerging threats to safe drinking water. Disinfection of drinking water is one of the major public health advances in the 20th century. One hundred years ago, typhoid and cholera epidemics were common through American cities; disinfection was a major factor in reducing these epidemics.

In the past 15 years, we have learned that there are specific microbial pathogens, such as Cryptosporidium, which can cause illness, and are highly resistant to traditional disinfection practices. We also know that the disinfectants themselves can react with naturally-occurring materials in the water to form byproducts, which may pose health risks.

Amendments to the SDWA in 1996 require EPA to develop rules to balance the risks between microbial pathogens and disinfection byproducts (DBPs). The Stage 1 Disinfectants and Disinfection Byproducts Rule and Interim Enhanced Surface Water Treatment Rule, promulgated in December 1998, were the first phase in a rulemaking strategy required by Congress as part of the 1996 Amendments to the Safe Drinking Water Act.

The Long Term 2 Enhanced Surface Water Treatment Rule builds upon earlier rules to address higher risk public water systems for protection measures beyond those required for existing regulations.

The Long Term 2 Enhanced Surface Water Treatment Rule and the Stage 2 Disinfection Byproduct Rule are the second phase of rules required by Congress. These rules strengthen protection against microbial contaminants, especially Cryptosporidium, and at the same time, reduce potential health risks of DBPs.

Questions and Answers

What is the LT2ESWTR?

The purpose of Long Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR) is to reduce illness linked with the contaminant Cryptosporidium and other pathogenic microorganisms in drinking water. The LT2ESWTR will supplement existing regulations by targeting additional Cryptosporidium treatment requirements to higher risk systems. This rule also contains provisions to reduce risks from uncovered finished water reservoirs and provisions to ensure that systems maintain microbial protection when they take steps to decrease the formation of disinfection byproducts that result from chemical water treatment.

Current regulations require filtered water systems to reduce source water Cryptosporidium levels by 2-log (99 percent). Recent data on Cryptosporidium infectivity and occurrence indicate that this treatment requirement is sufficient for most systems, but additional treatment is necessary for certain

higher risk systems. These higher risk systems include filtered water systems with high levels of Cryptosporidium in their water sources and all unfiltered water systems, which do not treat for

Cryptosporidium.

The LT2ESWTR is being promulgated simultaneously with the Stage 2 Disinfection Byproduct Rule to address concerns about risk tradeoffs between pathogens and DBPs.

What are the health risks of Cryptosporidium?

Cryptosporidium is a significant concern in drinking water because it contaminates most surface waters used as drinking water sources, it is resistant to chlorine and other disinfectants, and it has caused waterborne disease outbreaks. Consuming water with Cryptosporidium can cause gastrointestinal illness, which may be severe and sometimes fatal for people with weakened immune systems (which may include infants, the elderly, and people who have AIDS).

Who must comply with this rule?

This regulation will apply to all public water systems that use surface water or ground water under the direct influence of surface water.

What does the rule require?

Monitoring: Under the LT2ESWTR, systems will monitor their water sources to determine treatment requirements. This monitoring includes an initial two years of monthly sampling for Cryptosporidium. To reduce monitoring costs, small filtered water systems will first monitor for E. coliCa bacterium which is less expensive to analyze than CryptosporidiumCand will monitor for Cryptosporidium only if their E. coli results exceed specified concentration levels.

Monitoring starting dates are staggered by system size, with smaller systems beginning monitoring after larger systems. Systems must conduct a second round of monitoring six years after completing the initial round to determine if source water conditions have changed significantly. Systems may use (grandfather) previously collected data in lieu of conducting new monitoring, and systems are not required to monitor if they provide the maximum level of treatment required under the rule.

Cryptosporidium treatment: Filtered water systems will be classified in one of four treatment categories (bins) based on their monitoring results. The majority of systems will be classified in the lowest treatment bin, which carries no additional treatment requirements. Systems classified in higher treatment bins must provide 90 to 99.7 percent (1.0 to 2.5-log) additional treatment for Cryptosporidium. Systems will select from a wide range of treatment and management strategies in the Amicrobial toolbox@ to meet their additional treatment requirements. All unfiltered water systems must provide at least 99 or 99.9 percent (2 or 3-log) inactivation of Cryptosporidium, depending on the results of their monitoring. These Cryptosporidium treatment requirements reflect consensus recommendations of the Stage 2 Microbial and Disinfection Byproducts Federal Advisory Committee.

Other requirements: Systems that store treated water in open reservoirs must either cover the reservoir or treat the reservoir discharge to inactivate 4-log virus, 3-log Giardia lamblia, and 2-log Cryptosporidium. These requirements are necessary to protect against the contamination of water that occurs in open reservoirs. In addition, systems must review their current level of microbial treatment before making a significant change in their disinfection practice. This review will assist systems in maintaining protection against microbial pathogens as they take steps to reduce the formation of disinfection byproducts under the Stage 2 Disinfection Byproducts Rule, which EPA is finalizing along with the LT2ESWTR.

What are the benefits of the rule?

The LT2ESWTR will improve the control of Cryptosporidium and other microbiological pathogens in drinking water water systems with the highest risk levels. EPA estimates that full compliance with the LT2ESWTR will reduce the incidence of cryptosporidiosis – the gastrointestinal illness caused by ingestion of Cryptosporidium – by 89,000 to 1,459,000 cases per year, with an associated reduction of 20 to 314 premature deaths. The monetized benefits associated with these reductions ranges from $253 million to $1.445 billion per year. The additional Cryptosporidium treatment requirements of the LT2ESWTR will also reduce exposure to other microbial pathogens, such as Giardia, that co-occur with Cryptosporidium. Additional protection from microbial pathogens will come from provisions in this rule for reviewing disinfection practices and for covering or treating uncovered finished water reservoirs, though EPA has not quantified these benefits.

What are the costs of the rule?

The LT2ESWTR will result in increased costs to public water systems and states. The average annualized present value costs of the LT2ESWTR are estimated to range from $92 to $133 million (using a three percent discount rate). Public water systems will bear approximately 99 percent of this total cost, with states incurring the remaining 1 percent. The average annual household cost is estimated to be $1.67 to $2.59 per year, with 96 to 98 percent of households experiencing annual costs of less than $12 per year.

What technical information will be available on the rule?

The following guidance documents will be available:

  • • Source Water Monitoring Guidance
  • • Microbial Laboratory Guidance
  • • Small Entity Compliance Guidance
  • • Microbial Toolbox Guidance Manual
  • • Ultraviolet Disinfection Guidance Manual
  • • Membrane Filtration Guidance Manual
  • • Simultaneous Compliance Guidance Manual
  • • Low-pressure Membrane Filtration for Pathogen Removal: Application, Implementation, and Regulatory Issues

Where can I find more information about this notice and the LT2ESWTR?

For general information on the LT2ESWTR, contact the Safe Drinking Water Hotline at (800) 426-4791. The Safe Drinking Water Hotline is open Monday through Friday, excluding legal holidays, from 10:00 a.m. to 4:00 p.m., Eastern time. For copies of the Federal Register notice of the regulation or technical fact sheets, visit the EPA Safewater website at  http://www.epa.gov/safewater/disinfection/lt2. For technical inquiries, email  stage2mdbp@epa.gov.

Office of Water (4607M) EPA 815-F-05-009 December 2005   www.epa.gov/safewater

Giardia

Giardia – A protozoan parasite.  Occurrence in water sample must be confirmed by identification of two or more morphological
characteristics, nuclei, axoneme and/or median body.

How are MPA groundwater tests conducted?

Samples are collected in accordance with the EPA “Consensus
Method for Determining Groundwaters Under the Direct Influence
of Surface Water Using Microscopic Particulate Analysis (MPA).”
Two sampling events are recommended, one during a dry period and
a second during a wet period.  Turbidity, temperature, rainfall and
stream flow records, and conductivity etc. may be used for guidance
for when to test.

What is MPA and how can it be used to differentiate ground water under surface influence?

What is MPA and how can it be used to differentiate ground
water under surface influence?
The premise behind the use of microscopic particulate analysis
(MPA) is that surface waters are subject to contamination by
pathogens such as Giardia and that there are other organisms whose
natural habitat is limited to surface waters.  If these surface water
organisms are found in ground water, then the water is subject to
contamination with Giardia cysts and other pathogens.  Indicators of
surface water contamination of ground waters include: Giardia,
coccidia including Cryptosporidium, diatoms and certain other algae,
rotifers, green plant material, and insect parts. 

What information is useful in MPA classification?

Historical water quality records
1.  At least three years of Total Coliform and/or Fecal Coliform data.
2.  Turbidity and temperature records including those of nearby
surface water sources.
3.  No history of a known or suspected outbreak of Giardia,
Cryptosporidium or other pathogenic organisms associated with
surface water that has been attributed to the source.
4.  No evidence of particulate matter associated with surface water.
On site inspection
1.  No evidence for surface water infiltration.
2.  Sufficient distances from surface water sources.Cryptosporidium
Cymbella (Diatom)

MPA – What is GWUDI – “a ground water source under direct influence of surface water”?

The EPA Guidance Manual defines a ground water source under
direct influence of surface water as water in which there is either:
“significant occurrence of insects or macroorganisms, algae, organic
debris, or large-diameter pathogens such as Giardia lamblia.”
or
“significant and relatively rapid shifts in water characteristics such
as turbidity, temperature, conductivity, or pH which closely correlate
to climatological or surface water condition.”

 

Receive an MPA GWUDI Quote by Clicking Here.

What is the LT2?

40549D 

The EPA Long-Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR or LT2)  will require utilities greater than 10,000 to sample once or twice a month for Cryptosporidium for twenty four months.  Based on the result of the monitoring the utility will be assigned a “bin” and a required level of treatment.  A utility might be required to upgrade treatment based on the results of the tests.